An improved method for the calibration of continuously recorded dye dilution curves.
نویسندگان
چکیده
ONE of the main problems in the use of continuously recorded dye dilution curves has been the calibration of the obtained curves. Methods involving measurements from the "tail" of the dilution curve are often inaccurate because in this portion of the curve the concentration of dye is low. Other methods of calibration involve determinations from a sample of blood withdrawn before or after the dilution curve has been recorded. A method of calibration has been developed which avoids many of these difficulties. I t involves the use of a sample of the same blood which is being withdrawn through the cuvette for the inscription of the dye curve and is therefore of a much higher concentration. The calibration is carried out by determining the mean concentration of dye in the sample and determining the mean deflection over the period of the collection.
منابع مشابه
Indicator dilution curves in atrial septal defect.
The indicator dilution technique has evolved into an invaluable method for the detection and localization of congenital and acquired cardiac shunts. The groundwork for much of the work in this field has been laid by Wood, Swan, and Helmholz (1957); Swan (1959); Hetzel, Swan, and Wood (1959); Braunwald, Tanenbaum, and Morrow (1958) and Braunwald and Morrow (1960). Indocyanine green is the most c...
متن کاملAbnormal Indicator Dilution Patterns in Dogs Produced by Flowmeter Probes on the Pulmonary Artery.
• Indicator dilution technics have been employed by Malooly and co-workers J for the in vivo calibration of electromagnetic flowmeter probes. In attempting to apply this calibration procedure to the measurement of pulmonary arterial flow in anesthetized dogs, we noted that the presence of the flowmeter probe on the pulmonary artery was frequently associated with abnormal indicator dilution curv...
متن کاملA photoelectric ear densitometer for continuously recording the arterial concentration of T-1824 in the dye-dilution method.
To eliminate the collection of serial samples of arterial blood an instrument has been developed which records dye-dilution curves by measuring changes in optical density of a segment of a heatflushed ear. Comparison with curves from arterial samples shows close similarity in the shape of the curves, and good agreement between the cardiac outputs calculated from them. Other advantages of the te...
متن کاملThe Use of the Ear Oximeter for Measurement of the Cardiac Output During Walking Exercise in Human Subjects ‡
For the study of walking exercise in human subjects, an accurate method for measurement of the cardiac output is needed which can be applied repeatedly and with minimal discomfort to the subject. Continuous recording of dye-dilution curves by means of an ear oximeter has been used previously,"'9'10 for estimating the cardiac output at rest, and requires only venipuncture. However, the accuracy ...
متن کاملIntrarenal distribution of blood flow in man. A new analytical method for dye-dilution curves.
To measure blood flow through fast and slow pathways of the kidney separately, a new method of analyzing dye-dilution curves was devised. Twenty-five patients with hypertension or renal disease were selected for study. Indocyanine green was injected into one renal artery and dye-dilution curves were recorded in blood from the ipsilateral renal vein, using a densitometer. Recirculation effect wa...