Evaluation of inertial measurement units as a novel method for kinematic gait evaluation in dogs.

نویسندگان

  • Felix M Duerr
  • Alexandra Pauls
  • Chris Kawcak
  • Kevin Haussler
  • Gina Bertocci
  • Valerie Moorman
  • Melissa King
چکیده

OBJECTIVE To evaluate the use of inertial measurement units (IMU) for quantification of canine limb kinematics. METHODS Sixteen clinically healthy, medium-sized dogs were enrolled. Baseline kinematic data were acquired using an optical motion capture system. Following this baseline data acquisition, a harness system was used for attachment of IMU to the animals. Optical kinematic data of dogs with and without the harness were compared to evaluate the influence of the harness on gait parameters. Sagittal plane joint kinematics acquired simultaneously with IMU and the optical system were compared for the carpal, tarsal, stifle and hip joints. Comparisons of data were made using the concordance correlation coefficient (CCC) test and evaluation of root mean squared errors (RMSE). RESULTS No significant differences were demonstrated in stance duration, swing duration or stride length between dogs instrumented with or without the harness, however, mean RMSE values ranged from 4.90° to 14.10° across the various joints. When comparing simultaneously acquired optical and IMU kinematic data, strong correlations were found for all four joints evaluated (CCC: carpus = 0.98, hock = 0.95, stifle = 0.98, hip = 0.96) and median RMSE values were similar across the joints ranging from 2.51° to 3.52°. CONCLUSIONS AND CLINICAL RELEVANCE Canine sagittal plane motion data acquisition with IMU is feasible, and optically acquired and IMU acquired sagittal plane kinematics had good correlation. This technology allows data acquisition outside the gait laboratory and may provide an alternative to optical kinematic gait analysis for the carpal, tarsal, stifle, and hip joints in the dog. Further investigation into this technology is indicated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of optimal step length in a seven-link model with margin of stability method

In a walking cycle design, maximizing the upright balance should be considered in addition to the kinematic constraints, energy consumption rate must be considered. The purpose of this study is to find the optimal step length obtained for each person according to the physical features. In this research, in order to minimize energy consumption rate by considering maximum balance two cost functio...

متن کامل

A Novel System-Level Calibration Method for Gimballed Platform IMU Using Optimal Estimation

An accurate calibration of inertial measurement unit errors is increasingly important as the inertial navigation system requirements become more stringent. Developing calibration methods that use as less as possible of IMU signals has 6-DOF gimballed IMU in space-stabilized mode is presented. It is considered as held stationary in the test location incorporating 15 di...

متن کامل

The effect of levodopa on postural stability evaluated by wearable inertial measurement units for idiopathic and vascular Parkinson's disease.

BACKGROUND Postural stability analysis has shown that postural control is impaired in untreated idiopathic Parkinson's disease (IPD), even in the early stages of the disease. Vascular Parkinson's disease (VPD) lacks consensus clinical criteria or diagnostic tests. Moreover, the levodopa effect on postural balance remains undefined for IPD and even less so for VPD. OBJECTIVE To characterize po...

متن کامل

Evaluation of the Performances of Two Wearable Systems for Gait Analysis: A Pilot Study

Introduction: Wearable sensor systems to perform human motion analysis are receiving increasing attention in different application fields. Among wearable sensors, inertial sensors have promising features. However, before they can be employed routinely in clinical applications, it is important to evaluate their reliability. Gait analysis was performed on one male volunteer: data were simultaneou...

متن کامل

A Wearable Gait Analysis System using Inertial Sensors Part I - Evaluation of Measures of Gait Symmetry and Normality against 3D Kinematic Data

Gait analysis (GA) is an important tool in the assessment of several physical and cognitive conditions. The lack of simple and economically viable quantitative GA systems has hindered the routine clinical use of GA in many areas. As a result, patients may be receiving sub-optimal treatment. The present study introduces and evaluates measures of gait symmetry and gait normality calculated from i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Veterinary and comparative orthopaedics and traumatology : V.C.O.T

دوره 29 6  شماره 

صفحات  -

تاریخ انتشار 2016