Effect of probe pressure on cervical fluorescence spectroscopy measurements.
نویسندگان
چکیده
Fluorescence spectroscopy is a promising technology for detection of epithelial precancers and cancers. While age and menopausal status influence measurements in the cervix, other variables do not significantly affect the diagnosis. In this study we examine probe pressure as a variable. A fiber optic probe to measure fluorescence spectra at different calibrated levels of pressure was designed and tested. A pilot study was conducted measuring fluorescence excitation emission matrices in 20 patients at light, medium, and firm pressure. Spectroscopic data were pre-processed and analyzed to compare mean peak intensities as a function of pressure. Further statistical analyses tested for differences in intensities at each excitation/emission wavelength pair. Four providers made measurements from 41 sites; 33 yielded good quality spectroscopic data (22 squamous normal, 7 squamous abnormal, 3 columnar normal, 1 transformation zone) from 17 of 20 patients. At all pressure levels, abnormal tissue showed less fluorescence intensity than normal tissue, and post-menopausal patients showed higher fluorescence intensity than premenopausal patients, consistent with previous analyses. A permutation analysis suggests that pressure does not significantly affect fluorescence intensity or lineshape. While other studies are needed to confirm these findings, this study suggests that fluorescence spectroscopy is a robust technology likely not influenced by fiber optic probe pressure.
منابع مشابه
Probe pressure effects on human skin diffuse reflectance and fluorescence spectroscopy measurements.
Diffuse reflectance and fluorescence spectroscopy are popular research techniques for noninvasive disease diagnostics. Most systems include an optical fiber probe that transmits and collects optical spectra in contact with the suspected lesion. The purpose of this study is to investigate probe pressure effects on human skin spectroscopic measurements. We conduct an in-vivo experiment on human s...
متن کاملEvaluation and Characterization of Free and Immobilized Acethylcholinesterase with Fluorescent Probe, Differential Scanning Calorimetry and Docking
Acetylcholinesterase (AChE) enzyme which catalyses the hydrolysis of choline esters, such as acetylcholine, is very important in nerve function. Previous structural studies showed the possible amyloid fibril formation on the AChE. Therefore it is important to understand interaction of ligands to prevent the formation of amyloid fibrils. The purpose of the present study was to char...
متن کاملThe performance of fluorescence and reflectance spectroscopy for the in vivo diagnosis of cervical neoplasia; point probe versus multispectral approaches.
OBJECTIVE This review evaluates the diagnostic efficacy of fluorescence spectroscopy, reflectance spectroscopy, and their combination that use both point probe and multispectral imaging approaches in diagnosing cervical neoplasia in vivo. METHODS Articles were selected for this review from a literature search which report the performance of fluorescence and reflectance spectroscopy devices in...
متن کاملEffects of probe geometry on transscleral diffuse optical spectroscopy
The purpose of this study was to investigate how the geometry of a fiber optic probe affects the transmission and reflection of light through the scleral eye wall. Two geometrical parameters of the fiber probe were investigated: the source-detector distance and the fiber protrusion, i.e. the length of the fiber extending from the flat surface of the fiber probe. For optimization of the fiber op...
متن کاملReproducibility and repeatability of measuring the electrical impedance of the pregnant human cervix-the effect of probe size and applied pressure
BACKGROUND The utility of cervical electrical impedance spectroscopy (EIS) as a diagnostic tool is being investigated in clinical trials. We sought to assess the reliability of two different sizes of tetrapolar probes used in measuring cervical impedance. METHODS Cervical transfer impedance was measured at 14 frequencies between 76 and 625 000 Hz from 11 pregnant subjects at term. Repeated me...