Caffeine clearance by enzyme multiplied immunoassay technique: a simple, inexpensive, and useful indicator of liver function.
نویسندگان
چکیده
The clinical value and sensitivity of serum caffeine clearance measurement has been evaluated as an indicator of hepatic disease. After a 17 hour caffeine exclusion period, 300 mg of caffeine citrate was administered orally to the study subjects. Serum samples were taken four and 16 hours later. Serum caffeine concentrations were measured using an enzyme multiplied immunoassay technique (EMIT) and a clearance value derived. Conventional liver function tests were measured at the same time. A total of 103 subjects attending the medical unit in a district general hospital were studied. Twenty one had alcoholic liver disease, 11 non-alcoholic cirrhosis, nine non-cirrhotic liver disease, 21 suspected liver disease, six hepatic tumours, and 35 were hospital and normal control subjects. Caffeine clearance values were lowest in subjects with alcoholic liver disease (median 0.19 ml/min/kg, range 0.04-0.61 ml/min/kg) and significantly reduced in all subjects with liver disease (median 0.32 ml/min/kg, range 0.04-2.68 ml/min/kg) compared with control subjects (median 1.27 ml/min/kg, p less than 0.001). In subjects with suspected liver disease subsequently shown to have another explanation for abnormal liver function test results, caffeine clearance values were normal (median 1.31 ml/min/kg, range 0.23-2.64 ml/min/kg) and significantly different, p less than 0.001, from those of subjects with liver disease. Serum albumen values were not different for these latter two groups. Using a cut off value of 0.86 ml/min/kg, caffeine clearance measurement was 100% sensitive for alcoholic liver disease and 89% sensitive for all liver disease. The respective sensitivities for conventional liver function test measurement were 76% and 83%. In the suspected liver disease group, caffeine clearance was abnormal in only 24%, conventional liver function tests were abnormal in 95%. The respective specificities for caffeine clearance and liver function test measurement in control subjects were 93% and 100%. Caffeine clearance determined by EMIT is a simple inexpensive hepatic metabolic function test. This study indicates that it is a more sensitive indicator of structural liver disease than conventional liver function tests, especially for alcoholic liver disease. The test could be widely introduced as a useful, repeatable assessment of hepatic function.
منابع مشابه
Development of a Latex Agglutination Method for Diagnosis of Rotavirus Infections
Background: Rotavirus is a major cause of morbidity and mortality among children with gastroenteritis. Since the discovery of rotaviruses, several techniques have been used for their laboratory diagnosis; those included Electron Microscopy (EM) and enzyme immunoassay. These methods, however, are expensive and not readily available everywhere. We have developed a technique which can be used for ...
متن کاملAutomated computer analysis for enzyme-multiplied immunological techniques.
The dose/response curve in enzyme-multiplied immunoassays (EMIT) and related techniques may be described by the same "four-parameter logistic function" as has proven useful in radioimmunoassays, immunoradiometric assays (IRMA), and two-site immunoradiometric ("sandwhich") assays. This function provides an empirical description of the dose/response curve by use of an objective least-squares regr...
متن کاملTissue distribution of amphetamine isomers in a fatal overdose.
A young man (22 years old) died of a cardiorespiratory arrest a few hours following admission to the emergency department of a hospital. He was found lying seriously ill in the parking lot of a dance club. Screening of postmortem blood and urine with enzyme multiplied immunoassay (EMIT) detected only amphetamines, caffeine, and cotinine. Further screening of blood, urine, and stomach contents w...
متن کاملComparison of enzyme-multiplied immunoassay technique with fluorescence polarization immunoassay for determination of gentamicin and tobramycin levels in serum.
We assayed serum gentamicin and tobramycin specimens by the enzyme multiplied immunoassay technique (Syva EMIT) and the fluorescence polarization immunoassay (Abbott TDx). When interassay and intraassay control samples were evaluated, both methods gave an overall coefficient of variation of less than +/- 10%. Using patient serum samples, we obtained excellent correlation with both methods in th...
متن کاملبررسی فعالیت آنزیمهای کبدی GGT،ALP،ALT،AST در سرم بیماران تحت جراحی سیستم عصبی قبل و پس از بیهوشی عمومی با داروی استنشاقی ایزوفلوران
Background and Aim: Isoflurane is one of the selective and mostly-used respiratory anesthetic materials in the field of neurosurgery. Studies have shown that temporary rise in the level of liver enzymes may occur after anesthesia by halogenic ethers and hence cause liver lesions. The aim of this study was to investigate the effects of isoflurane on the activity of ALT-AST-ALP-GGT enzymes...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Gut
دوره 32 6 شماره
صفحات -
تاریخ انتشار 1991