An automated calibration method for non-see-through head mounted displays

نویسندگان

  • Stuart Gilson
  • Andrew W. Fitzgibbon
  • Andrew Glennerster
چکیده

Accurate calibration of a head mounted display (HMD) is essential both for research on the visual system and for realistic interaction with virtual objects. Yet, existing calibration methods are time consuming and depend on human judgements, making them error prone, and are often limited to optical see-through HMDs. Building on our existing approach to HMD calibration Gilson et al. (2008), we show here how it is possible to calibrate a non-see-through HMD. A camera is placed inside a HMD displaying an image of a regular grid, which is captured by the camera. The HMD is then removed and the camera, which remains fixed in position, is used to capture images of a tracked calibration object in multiple positions. The centroids of the markers on the calibration object are recovered and their locations re-expressed in relation to the HMD grid. This allows established camera calibration techniques to be used to recover estimates of the HMD display's intrinsic parameters (width, height, focal length) and extrinsic parameters (optic centre and orientation of the principal ray). We calibrated a HMD in this manner and report the magnitude of the errors between real image features and reprojected features. Our calibration method produces low reprojection errors without the need for error-prone human judgements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Calibration Procedures for Optical See-Through Head-Mounted Displays

Optical see-through head-mounted displays (HMDs) are less commonly used because they are difficult to accurately calibrate. In this article, we report a user study to compare the accuracy of 4 variants of the SPAAM calibration method. Among the 4 variants, Stylus-marker calibration, where the user aligns a crosshair projected in the HMD with a tracked stylus tip, achieved the most accurate resu...

متن کامل

Single point active alignment method (SPAAM) for optical see-through HMD calibration for AR

Augmented reality (AR) is a technology in which a user’s view of the real world is enhanced or augmented with additional information generated from a computer model. In order to have a working AR system, the see-through display system must be calibrated so that the graphics is properly rendered. The optical see-through systems present an additional challenge because we do not have access to the...

متن کامل

INDICA : Interaction-free display calibration for optical see-through head-mounted displays based on 3D eye localization

A correct spatial registration of Optical See-Through HeadMounted Displays (OST-HMD) w.r.t. a user’s eye(s) is an essential problem for any AR application using the such HMDs (Fig. 1). Maintaining the correct registration demands frequent (re)calibrations for the end-users whenever they move the HMD on their head. Thus, a calibration technique should be simple and accurate for the universal, lo...

متن کامل

Optical see-through HMD calibration: a stereo method validated with a video see-through system

This paper presents initial results from an ongoing work to calibrate optical see-through head-mounted displays (HMDs). We have developed a method to calibrate stereoscopic optical see-through HMDs based on the 3D alignment of a target in the physical world with a virtual object in user’s view. This is an extension of the Single Point Active Alignment Method (SPAAM) [28] developed for monocular...

متن کامل

A method for calibrating see-through head-mounted displays for AR

In order to have a working AR system, the see-through system must be calibrated such that the internal models of objects match their physical counterparts. By match, we mean they should have the same position, orientation, and size information as well as any intrinsic parameters (such as focal lengths in the case of cameras) that their physical counterparts have. To this end, a procedure must b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 199  شماره 

صفحات  -

تاریخ انتشار 2009