Edge‐detection of the radiation field in double exposure portal images using a curve propagation algorithm

نویسندگان

  • Patricia Lasserre
  • Bryce Cutt
  • James Moffat
چکیده

An accurate detection of the radiation field is crucial to 3D conformal radiotherapy (3D-CRT). Automated techniques to detect the field edges on double exposure portal images have previously focused on thresholding techniques. In this paper, we present a new approach based on a curve propagation technique (the Fast Marching method) which proves to be more effective at detecting the radiation field than its thresholding counterpart. The comparison of both techniques in terms of computational speed and effectiveness of the detection is presented using complex images with non-homogeneous intensity levels inside the radiation field, and gradual variations in intensity level at the field boundaries. Results show that our Fast Marching method is easier to automate, and converges faster to the boundaries of the segmented radiation field. The computation time of the Fast Marching technique is five times faster in typical portal images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Portal Imaging System Performance for an Elekta Precise Linac in Radiotherapy

Introduction: Electronic portal imaging devices (EPIDs) provide two- and three-dimensional planar and volumetric cone beam images to improve the accuracy of radiation treatment delivery. Periodic quality assurance (QA) of EPIDs is essential for dosimetric verification in radiotherapy. In this study, a QA program was implemented to evaluate the function of the EPID to be confident in applying co...

متن کامل

Standard edge detection algorithms versus conventional auto-contouring used for a three-dimensional rigid CT-CT matching

Background: To reduce uncertainties of patient positioning, the Computerized Tomography (CT) images acquired at the treatment planning time can be compared with those images obtained during radiation dose delivery. This can be followed during dose delivery procedure as Image Guided radiotherapy (IGRT) to verify the prescribed radiation dose delivery to the target as well as to monitor ...

متن کامل

Noisy images edge detection: Ant colony optimization algorithm

The edges of an image define the image boundary. When the image is noisy, it does not become easy to identify the edges. Therefore, a method requests to be developed that can identify edges clearly in a noisy image. Many methods have been proposed earlier using filters, transforms and wavelets with Ant colony optimization (ACO) that detect edges. We here used ACO for edge detection of noisy ima...

متن کامل

Enhancing magnetic signals in unexploded ordnances (UXO) detection based on edge-preserved stable downward continuation method

This paper describes an efficient edge-preserved regularization algorithm for downward continuation of magnetic data in detection of unexploded ordnance (UXO). The magnetic anomalies arising from multi-source UXO can overlap at a height over the ground surface, while causative sources may not be readily separated due to low level of signal-to-noise ratio of the observed data. To effectively the...

متن کامل

A FUZZY DIFFERENCE BASED EDGE DETECTOR

In this paper, a new algorithm for edge detection based on fuzzyconcept is suggested. The proposed approach defines dynamic membershipfunctions for different groups of pixels in a 3 by 3 neighborhood of the centralpixel. Then, fuzzy distance and -cut theory are applied to detect the edgemap by following a simple heuristic thresholding rule to produce a thin edgeimage. A large number of experime...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2008