Investigating the potential benefits of a new artificial tear formulation combining two polymers

نویسندگان

  • Peter A Simmons
  • Joseph G Vehige
چکیده

PURPOSE Artificial tear formulations typically contain a water-soluble polymer to enhance residence time, moisture retention, and binding to the mucin coat of the ocular surface, which facilitate corneal healing. This study investigated the potential advantages of combining carboxymethylcellulose (CMC) and hyaluronic acid (HA) polymers in a single formulation. MATERIALS AND METHODS Individual CMC and HA solutions were prepared and tested for bulk viscosity in comparison to a solution that combined CMC and HA. Rheometry determined the differences between solutions at increasing shear rates, simulating eye movement and blinking. RESULTS The bulk viscosity of the individual 0.5% CMC and 0.1% HA solutions was 2.5 and 5.7 cP, respectively. The viscosity of the combined solution (13.1 cP) was 60% higher than predicted by additive effects. Rheometry revealed shear rates between 10/second (open eye) and 10,000/second (blinking eye). At these rates, viscosity ranged from 2.7 to 3.5 cP for 0.5% CMC, 2.8 to 6.8 cP for 0.1% HA, and 5.2 to 15.3 cP for the 0.5% CMC-0.1% HA combination. Low-shear viscosity of the CMC-HA combination increased 48% over the sum of the individual solutions, but high-shear viscosity remained virtually unchanged. Data from CMC and HA solutions at higher concentrations were consistent with these results. CONCLUSION Combining CMC and HA polymers produced a synergistic increase in low-shear viscosity (which cannot be fully explained by simple molecular entanglement), while the high-shear viscoelasticity of the combined solution remained unaffected. These data suggest that CMC-HA combinations have properties that may be used to formulate artificial tears that optimize ocular retention (through higher low-shear viscosity), while minimizing blur and stickiness during blinking (through lower high-shear viscosity).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Influence of Various Mucoadhesive Polymers on In Vitro Performance of the Resulting Artificial Saliva Pump Spray Formulations

The aim of this study was to investigate the rheological behavior and mucoadhesive nature of saliva substitutes, by incorporating various mucoadhesive polymers into an artificial saliva pump spray formulation. For this purpose various mucoadhesive polymers including cellulosic polymers in the range of 0.1-1.0% and Carbomers such as C974p, C971, C934p and C971 in the range of 0.01-0.1% were adde...

متن کامل

The Influence of Various Mucoadhesive Polymers on In Vitro Performance of the Resulting Artificial Saliva Pump Spray Formulations

The aim of this study was to investigate the rheological behavior and mucoadhesive nature of saliva substitutes, by incorporating various mucoadhesive polymers into an artificial saliva pump spray formulation. For this purpose various mucoadhesive polymers including cellulosic polymers in the range of 0.1-1.0% and Carbomers such as C974p, C971, C934p and C971 in the range of 0.01-0.1% were adde...

متن کامل

P 120 Determination of the tear volume as a method of assessing the precorneal residence time of various polymer formulations in rabbits

Purnose The incorporation of polymers into artificial tears both increases the thickness of the precorneal tear film and decreases the rate of drainaae of the for8nulations. On the basis of these effects, we hypothesized that a time study of the artificial increase in tear volume induced by such formulations could be a useful method of assessing their precorneal residence time. Methods New Zeal...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017