The effects of nocturnal home mechanical ventilation on daytime blood gas disturbances.
نویسندگان
چکیده
INTRODUCTION In chronic alveolar hypoventilation, previous studies of selected patient groups have shown that nocturnal home mechanical ventilation (HMV) may result in improvements in chronic blood gas disturbances during daytime spontaneous breathing. We wished to examine the effects of this treatment in a large sample of non-selected patients prospectively followed up, in a national multicentric register. MATERIAL A total of 288 patients from a broad diagnostic spectrum were studied. We looked at the blood gases and vital capacity before the patients elected for initiation of HMV and at the first register-recorded follow-up after 6-24 months. RESULTS We found statistically significant improvements in PO(2) and PCO(2) (approximately 1 kPa in both) and in base excess, but no changes in vital capacity or calculated alveolo-arterial gradient. All changes were independent of the observation period and only weakly diagnose-related. DISCUSSION Our findings extend those of previous studies, showing a relatively early and apparently stable improvement in blood gases after starting and continuing nocturnal HMV. The equal extent of the improvements in blood gases among all the diagnostic groups including the neurological patients with progressive diseases was unexpected. CONCLUSION In 288 patients starting nocturnal HMV electively we found significant improvements in daytime blood gases after 6-24 months. There were no changes in vital capacity or calculated alveolo-arterial gradient.
منابع مشابه
EVect of non-invasive mechanical ventilation on sleep and nocturnal ventilation in patients with chronic respiratory failure
Background—Chronic respiratory failure (CRF) is associated with nocturnal hypoventilation. Due to the interaction of sleep and breathing, sleep quality is reduced during nocturnal hypoventilation. Noninvasive mechanical ventilation (NMV), usually performed overnight, relieves symptoms of hypoventilation and improves daytime blood gas tensions in patients with CRF. The time course of the long te...
متن کاملEffect of non-invasive mechanical ventilation on sleep and nocturnal ventilation in patients with chronic respiratory failure.
BACKGROUND Chronic respiratory failure (CRF) is associated with nocturnal hypoventilation. Due to the interaction of sleep and breathing, sleep quality is reduced during nocturnal hypoventilation. Non-invasive mechanical ventilation (NMV), usually performed overnight, relieves symptoms of hypoventilation and improves daytime blood gas tensions in patients with CRF. The time course of the long t...
متن کامل[Daytime mechanical ventilation in chronic ventilatory insufficiency].
BACKGROUND Nocturnal hypoventilation is associated with chronic ventilatory insufficiency (CVI). Noninvasive mechanical ventilation (NIV) performed overnight relieves symptoms of hypoventilation and improves daytime blood gases in CVI. In order to test whether the efficacy of NIV depends on its being applied during sleep we conducted a prospective case controlled study comparing daytime mechani...
متن کاملMechanisms underlying effects of nocturnal ventilation on daytime blood gases in neuromuscular diseases.
The hypothesis that, in neuromuscular and chest wall diseases, improvement in central respiratory drive explains the effects of night-time ventilation on diurnal gas exchanges was tested. The effects at 6 months, 1, 2 and 3 yrs of intermittent positive pressure ventilation (IPPV) on arterial blood gas tension, pulmonary function, muscle strength, sleep parameters, respiratory parameters during ...
متن کاملThe effects of one year of nocturnal cuirass-assisted ventilation in chest wall disease.
The effects of one year of nocturnal cuirass-assisted ventilation using individually designed cuirass respirators have been investigated in twenty-five patients with chest wall disease. After one year, 22 (88%) of the patients were alive. Daytime arterial blood gases had improved. Functional residual capacity (FRC) had increased but there was no significant change in other lung volumes. Maximum...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical physiology and functional imaging
دوره 26 2 شماره
صفحات -
تاریخ انتشار 2006