Evaluation of new monoclonal antibody-based latex agglutination test for detection of cryptococcal polysaccharide antigen in serum and cerebrospinal fluid.
نویسندگان
چکیده
We evaluated the performance of CRYPTO-LEX (Trinity Laboratories, Inc., Raleigh, N. C.), a new mouse immunoglobulin M monoclonal antibody latex agglutination reagent which reacts with the capsular polysaccharide of the four serogroups of Cryptococcus neoformans. This test was compared with CALAS (Meridian Diagnostics, Cincinnati, Ohio) for the ability to detect cryptococcal antigen in serum and cerebrospinal fluid (CSF). A total of 580 clinical specimens (327 serum and 253 CSF samples), primarily from human immunodeficiency virus-infected patients, were tested in this study. Sixty-seven specimens (44 serum and 23 CSF samples) were positive for cryptococcal antigen with both tests, and 511 (282 serum and 229 CSF samples) were negative. The two latex reagents agreed for 326 of 327 serum specimens (44 positives and 282 negatives). One serum specimen with a titer of 1:2 was CALAS positive but CRYPTO-LEX negative. The titer correlation coefficient for the two tests was 0.884 when two highly discordant serum specimens were eliminated from analysis of the data. The two latex tests agreed for 252 of 253 CSF specimens (23 positives and 229 negatives). One specimen with a titer of 1:2 was positive with CALAS and negative by CRYPTO-LEX. The correlation coefficient of the two tests for CSF titers was 0.886. The sensitivity and specificity of CRYPTO-LEX were 97 and 100%, respectively, with a 99.6% correlation with CALAS. These data show that the performance of CRYPTO-LEX is comparable to that of CALAS for detection of cryptococcal antigen in serum and CSF.
منابع مشابه
Comparison of the PREMIER cryptococcal antigen enzyme immunoassay and the latex agglutination assay for detection of cryptococcal antigens.
A new enzyme immunoassay (EIA), PREMIER Cryptococcal Antigen, was compared with latex agglutination (LA) for the detection and quantitation of circulating capsular polysaccharide antigen from Cryptococcus neoformans. The clinical evaluation of PREMIER EIA as a screening assay, including 475 specimens with 120 LA and EIA positives, resulted in 99% sensitivity and 97% specificity. The clinical sp...
متن کاملLateral Flow Assay for Cryptococcal Antigen: an Important Advance to Improve the Continuum of Hiv Care and Reduce Cryptococcal Meningitis-related Mortality
AIDS-related cryptococcal meningitis continues to cause a substantial burden of death in low and middle income countries. The diagnostic use for detection of cryptococcal capsular polysaccharide antigen (CrAg) in serum and cerebrospinal fluid by latex agglutination test (CrAg-latex) or enzyme-linked immunoassay (EIA) has been available for over decades. Better diagnostics in asymptomatic and sy...
متن کاملInterference by hydroxyethyl starch used for vascular filling in latex agglutination test for cryptococcal antigen.
The glucuronoxylomannan component of the Cryptococcus neoformans capsular polysaccharide confers serotype specificity, and its detection in cerebrospinal fluid or serum by the latex agglutination test is used for diagnosis. Low-molecular-weight hydroxyethyl starches can be used as an alternative to albumin for vascular filling. This study reports the occurrence of a false-positive result with t...
متن کاملFalse-negative cerebrospinal fluid cryptococcal latex agglutination tests for patients with culture-positive cryptococcal meningitis.
Three cases of false-negative cerebrospinal fluid latex agglutination test results for patients with culture-positive cryptococcal meningitis are reported. False-negative results occurred in settings of low cryptococcal antigen concentrations in cerebrospinal fluid and were dependent on the latex agglutination test kit used. Investigation of each case revealed that prozone phenomena or interfer...
متن کاملNew cause for false-positive results with the cryptococcal antigen test by latex agglutination.
The highly specific and sensitive latex agglutination test for cryptococcal antigen detection in cerebrospinal fluid is routine in many hospitals. Contamination of cerebrospinal fluid by a minute amount of syneresis fluid (surface condensation) from agar gave a strongly positive reaction which was heat stable, was not eliminated by pronase treatment, and was not detected by the normal rabbit gl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 32 9 شماره
صفحات -
تاریخ انتشار 1994