Electron Microscope Radioautography as a Quantitative Tool in Enzyme Cytochemistry

نویسنده

  • M. M. Salpeter
چکیده

Tritiated diisopropylfluorophosphate (DFP) was used to phosphorylate acetylcholinesterase (AChase) in the motor end plate of mouse sternomastoid muscle, and its distribution within the end plate was evaluated quantitatively by electron microscope radioautography. With the use of emulsion layers whose sensitivity to tritium had been calibrated, the density of AChase in different components of the end plate was calculated. The AChase was primarily localized (85%) in the junctional fold region. The concentration of AChase there was more than 20,000 active sites per cubic micron of tissue. The resolution of the technique was not sufficient to determine whether there was some AChase in the nerve end bulb; however, if there is any there, the concentration must be less than 10% of that at the junctional fold region.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A QUANTITATIVE TOOL IN ENZYME CYTOCHEMISTRY I. The Distribution of Acetylcholinesterase at Motor End Plates of a Vertebrate Twitch Muscle

Tritiated diisopropylfluorophosphate (DFP) was used to phosphorylate acetylcholinesterase (AChase) in the motor end plate of mouse sternomastoid muscle, and its distribution within the end plate was evaluated quantitatively by electron microscope radioautography. With the use of emulsion layers whose sensitivity to tritium had been calibrated, the density of AChase in different components of th...

متن کامل

Absolute Sensitivity of Electron Microscope Radioautography

A calibration method is described for measuring absolute radioautographic sensitivities under various experimental conditions. Sensitivities to (3)H and (35)S radiation, i.e. ratio of developed grains to radioactive decays in the specimen, were determined with Ilford L4 and Kodak NTE emulsions. The highest values obtained in monolayers of emulsion were (1/8) for (3)H and 1/21 for (35)S. The inf...

متن کامل

Correlative fluorescence and electron microscopy on ultrathin cryosections: bridging the resolution gap.

Microscopy has become increasingly important for analysis of cells and cell function in recent years. This is due in large part to advances in light microscopy that facilitate quantitative studies and improve imaging of living cells. Analysis of fluorescence signals has often been a key feature in these advances. Such studies involve a number of techniques, including imaging of fluorescently la...

متن کامل

Resolution in Electron Microscope Radioautography

Experimental resolution values, half distances (HD), were determined for electron microscope radioautography with (14)C as the source of radioactivity. These were about a factor of 1.5-2 times higher than for tritium. Grain distributions normalized in units of HD were found to fit the "universal" curves previously obtained for tritium.

متن کامل

Electron Microscopic Radioautography of Thin Sections: the Golgi Zone as a Site of Protein Concentration in Pancreatic Acinar Cells

Electron microscopic radioautographs of guinea pig pancreatic exocrine cells were obtained by covering thin sections ( approximately 600 A) of OsO(4)-fixed, methacrylate-embedded tissue with thin layers of Ilford K-5 nuclear research emulsion. After an exposure of 13 days at 4 degrees C., the preparations were photographically processed, stained with uranyl acetate, and examined in an electron ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Cell Biology

دوره 42  شماره 

صفحات  -

تاریخ انتشار 1967