Cross-imaging system comparison of backscatter coefficient estimates from a tissue-mimicking material.

نویسندگان

  • Kibo Nam
  • Ivan M Rosado-Mendez
  • Lauren A Wirtzfeld
  • Viksit Kumar
  • Ernest L Madsen
  • Goutam Ghoshal
  • Alexander D Pawlicki
  • Michael L Oelze
  • Roberto J Lavarello
  • Timothy A Bigelow
  • James A Zagzebski
  • William D O'Brien
  • Timothy J Hall
چکیده

A key step toward implementing quantitative ultrasound techniques in a clinical setting is demonstrating that parameters such as the ultrasonic backscatter coefficient (BSC) can be accurately estimated independent of the clinical imaging system used. In previous studies, agreement in BSC estimates for well characterized phantoms was demonstrated across different laboratory systems. The goal of this study was to compare the BSC estimates of a tissue mimicking sample measured using four clinical scanners, each providing RF echo data in the 1-15 MHz frequency range. The sample was previously described and characterized with single-element transducer systems. Using a reference phantom for analysis, excellent quantitative agreement was observed across the four array-based imaging systems for BSC estimates. Additionally, the estimates from data acquired with the clinical systems agreed with theoretical predictions and with estimates from laboratory measurements using single-element transducers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of ultrasound attenuation and backscatter estimates in layered tissue-mimicking phantoms among three clinical scanners.

Backscatter and attenuation coefficient estimates are needed in many quantitative ultrasound strategies. In clinical applications, these parameters may not be easily obtained because of variations in scattering by tissues overlying a region of interest (ROI). The goal of this study is to assess the accuracy of backscatter and attenuation estimates for regions distal to nonuniform layers of tiss...

متن کامل

Backscatter coefficient measurements using a reference phantom to extract depth-dependent instrumentation factors.

In previous work, we demonstrated that accurate backscatter coefficient measurements are obtained with a data reduction method that explicitly accounts for experimental factors involved in recording echo data. An alternative, relative processing method for determining the backscatter coefficient and the attenuation coefficient is presented here. This method involves comparison of echo data from...

متن کامل

Ultrasonic attenuation and backscatter coefficient estimates of rodent-tumor-mimicking structures: comparison of results among clinical scanners.

In vivo estimations of the frequency-dependent acoustic attenuation (alpha) and backscatter (eta) coefficients using radiofrequency (rf) echoes acquired with clinical ultrasound systems must be independent of the data acquisition setup and the estimation procedures. In a recent in vivo assessment of these parameters in rodent mammary tumors, overall agreement was observed among alpha and eta es...

متن کامل

Tissue mimicking materials for a multi-imaging modality prostate phantom.

Materials that simultaneously mimic soft tissue in vivo for magnetic resonance imaging (MRI), ultrasound (US), and computed tomography (CT) for use in a prostate phantom have been developed. Prostate and muscle mimicking materials contain water, agarose, lipid particles, protein, Cu++, EDTA, glass beads, and thimerosal (preservative). Fat was mimicked with safflower oil suffusing a random mesh ...

متن کامل

Liquid or solid ultrasonically tissue-mimicking materials with very low scatter.

A new tissue-mimicking material for ultrasound, using evaporated milk as the primary absorption component, is described. It has very low backscatter but still exhibits the 1540 m s-1 propagation speed and proportionality of attenuation coefficient and frequency over the diagnostic frequency range. The material can be produced in solid or liquid form with attenuation coefficient slopes spanning ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 132 3  شماره 

صفحات  -

تاریخ انتشار 2012