[Left ventricular rupture of mitral valve prosthesis implantation treated using an intra-aortic balloon pump counterpulsation].

نویسندگان

  • Ovidio Alberto García-Villarreal
  • Bertín Ramírez-González
  • Martín A Saldaña-Becerra
چکیده

Left ventricular rupture is an infrequent but potentially fatal complication of mitral valve replacement. In spite of the fact that several methods of repair have previously been described, the mortality rate remains nearly 85%. The use of the intra-aortic balloon pump counterpulsation may increase the possibilities of success in the repair of this dreaded complication. We present here three cases of left ventricular rupture associated to mitral valve prosthesis implantation successfully treated with the aid of intra-aortic balloon pump counterpulsation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transfemoral transcatheter aortic valve implantation in a patient with a severe aortic stenosis and cardiogenic shock requiring intra-aortic balloon pump support

The following paper presents a patient with severe aortic stenosis and severely reduced left ventricular ejection fraction with intra-aortic balloon pump counterpulsation support, who underwent transfemoral aortic valve implantation of a CoreValve prosthesis.

متن کامل

Systematic review: Intra-aortic balloon counterpulsation pump therapy: a critical appraisal of the evidence for patients with acute myocardial infarction

Introduction Intra-aortic balloon counterpulsation pump (IABP) therapy has been used in several clinical situations, predominantly in critically ill patients, since 1968 [1]. In acute myocardial infarction (AMI) patients who are experiencing continued ischemia, IABP therapy may be used in an attempt to improve patency of an infarct-related coronary artery (IRA) and reduce the rates of recurrent...

متن کامل

Prolonged circulatory support with the intra-aortic balloon pump after myocardial infarction.

Circulation was supported by intra-aortic balloon counterpulsation for 30 and 38 days respectively in two patients with cardiogenic shock after acute myocardial infarction. One was flown 1400 km to Cape Town for heart transplantation but died after being weaned from the pump while awaiting a suitable donor. The other underwent successful surgical closure of a ruptured ventricular septum on the ...

متن کامل

Staphylococcus aureus bacteremia associated with intra-aortic balloon pumps.

To the Editor: Since its first clinical use in the late 1960s, intra-aortic balloon pump counterpulsation has been a significant means of supporting an inadequate myocardium.' The use of an intra-aortic balloon pump has increased greatly preceding open heart surgery for cardiogenic shock and left ventricular failure. Additional indications include other conditions such as unstable angina refrac...

متن کامل

Ischemic Colitis Caused by Intra-Aortic Balloon Pump Counterpulsation

Intra-aortic balloon pump counterpulsation (IABP) has been shown to prolong life in critically ill cardiac patients. However, complications including distal emboli, balloon rupture, bleeding, limb loss, and bowel ischemia continue to be associated with them. We present a case of a 56-year-old male who suffered bowel ischemia as a result of a malpositioned IABP. While the benefit of such devices...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Gaceta medica de Mexico

دوره 151 6  شماره 

صفحات  -

تاریخ انتشار 2015