Laboratory Characterization of a Commercial Capacitance Sensor for Estimating Permittivity and Inferring Soil Water Content

نویسندگان

  • Mike Schwank
  • Timothy R. Green
  • Christian Mätzler
  • Hannes Flühler
چکیده

Ring-capacitor sensors are used widely for real-time estimation of volumetric soil water content u from measured resonant frequency fr, which is directly affected by the bulk soil permittivity e. However, the relationship fr(e) requires improved quantification. We conducted laboratory experiments to characterize the response of the Sentek EnviroSMART sensor system for a full range of e values from air to water and a range of temperatures.Water–dioxanemixtureswere placed into a solvent-resistant container equipped with custom tools for heating and mixing the fluid, removing air bubbles from sensitive surfaces,measuring permittivity in situ, and creating an axisymmetric metal disturbance to the electric field. Total capacitance C was measured using a vector network analyzer (VNA) connected to one sensor, while four other sensors provided replicated fr readings. The measured temperature response of free water permittivity was linear with a negative slope, which is qualitatively consistent with theory. A precise nonlinear relationship between e and normalized fr was derived. The instrumental error in e was RMSEe 5 0.226 (for 3 , e , 43), which corresponds to a measurement precision in u(e) derived from Topp’s equation of RMSEu 5 0.0034 m m. Axisymmetric numerical simulations of the electric field supplemented the experimental results. The characteristic length scale for the distance measured radially from the access tube is 12.5 mm, meaning that 80 and 95% of the signal are sensed within approximately 20 and 37 mm of the access tube, respectively. The results are crucial for scientific applications of the investigated sensor type to environ-

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correcting the Temperature Influence on Soil Capacitance Sensors Using Diurnal Temperature and Water Content Cycles

The influence of temperature on the dielectric permittivity of soil is the result of counteracting effect that depends on the soil's composition and mineralogy. In this paper, laboratory experiments showed that for a given water content, the soil dielectric permittivity was linearly related to the temperature, with a slope (α) that varied between samples taken in the same soil. These variations...

متن کامل

Simultaneous Measurement of Soil Water Content and Salinity Using a Frequency-Response Method

where ε equals permittivity, εr equals relative permittivity, ε0 equals permittivity of free space (8.85 10 12 F Laboratory tests were conducted to simultaneously measure soil m 1), ε r equals dielectric constant (the real part of relawater content and salinity using a four-electrode Wenner array sensor. The sensor was modified to enhance the capacitive effect. Soil bulk tive permittivity), ε′′...

متن کامل

Frequency Dependence of the Complex Permittivity and Its Impact on Dielectric Sensor Calibration in Soils

tiveness of TDR. However, the emergence of low-cost, high-frequency oscillators has led to an increased interThe capacitance (CAP) method and time domain reflectometry est in CAP techniques (e.g., Dean et al., 1987; Evett (TDR) are two popular electromagnetic techniques used to estimate soil water content. However, the frequency dependence of the real and Steiner, 1995; Paltineanu and Starr, 19...

متن کامل

Fringe Capacitance Correction for a Coaxial Soil Cell

Accurate measurement of moisture content is a prime requirement in hydrological, geophysical and biogeochemical research as well as for material characterization and process control. Within these areas, accurate measurements of the surface area and bound water content is becoming increasingly important for providing answers to many fundamental questions ranging from characterization of cotton f...

متن کامل

Characterization of Soil-water Retention of a Very Gravelly Loam Soil Varied with Determination Method

Soil-water characteristic curves were determined for Krome calcareous very gravelly loam soil in the laboratory and in situ in an orchard. In the laboratory, soil-water retention was determined with a pressure plate and pressure Tempe cells for soil collected from vegetable fields. In the orchard, soil-water suction measured with tensiometers was compared to volumetric soil-water content (E) de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006