Changes of interstitial fluid volume in superficial tissues detected by a miniature ultrasound device.

نویسندگان

  • W Eichler
  • C Eisenbeiss
  • J Schumacher
  • S Klaus
  • R Vogel
  • K F Klotz
چکیده

We evaluated the changes of tissue layer thickness in circumscribed superficial tissue areas with a 10-MHz A-mode and a 20-MHz B-mode ultrasound device under alterations in body posture and plasma volume to detect fluid shifts between the different compartments. In 20 male volunteers, we measured tissue thickness by A mode and corium and subcutis thickness by B mode at the forehead before and 30 min after three procedures: change from upright to supine position (P1); change from upright to 30 degrees head-down-tilt position (P2); infusion of 10 ml/kg body wt of Ringer solution (P3). We found a significant correlation between baseline tissue thickness and the sum of corium and subcutis thicknesses (r = 0.75, P < 0.01). The changes of body posture and plasma volume resulted in significant increases of tissue thickness (P1, 2.9%; P2, 11.6%; P3, 5.8%) and corium thickness (P1, 4.7%; P2, 8.1%; P3, 9.1%) but not of the sum of chorium and subcutis thicknesses. We conclude that fluid shifts from the intravascular to the extravascular compartment are detectable by evaluating corium thickness with a B-mode, or more easily tissue thickness with an A-mode, ultrasound device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interstitial Fluid Presure. Ii. Pressure-volume Curves of Interstitial Space .

• In a previous study we found the interstitial fluid pressure, as measured in tissue cavities created by implanting perforated capsules, to be —6 to —7 mm Hg in most normal tissues, though it rose to positive values in edema. Very slight changes of interstitial fluid volume changed the interstitial fluid pressure markedly in normal tissues but only slightly in edematous tissues. The present st...

متن کامل

Relationship between interstitial fluid volume and pressure (compliance) in hypothyroid rats.

There is clinical and experimental evidence that lack of thyroid hormones may affect the composition and structure of the interstitium. This can influence the relationship between volume and pressure during changes in hydration. Hypothyrosis was induced in rats by thyroidectomy 8 wk before the experiments. Overhydration was induced by infusion of acetated Ringer, 5, 10, and 20% of the body weig...

متن کامل

Interstitial Glucose and Physical Exercise in Type 1 Diabetes: Integrative Physiology, Technology, and the Gap In-Between

Continuous and flash glucose monitoring systems measure interstitial fluid glucose concentrations within a body compartment that is dramatically altered by posture and is responsive to the physiological and metabolic changes that enable exercise performance in individuals with type 1 diabetes. Body fluid redistribution within the interstitial compartment, alterations in interstitial fluid volum...

متن کامل

Non-Invasive Determination of Blood Glucose Levels by Optical Waveguide

Objective: Today, there are various non-invasive techniques available for the determination of blood glucose levels. In this study, the level of blood glucose was determined by developing a new device using near-infrared (NIR) wavelength, glass optical waveguide, and the phenomenon of evanescent waves. Materials and Methods: The body's interstitial fluid has made possible the development of ne...

متن کامل

Interstitial Fluid Pressure: III. Its Effect on Resistance to Tissue Fluid Mobility

The resistance to fluid mobility in the interstitial fluid spaces has been measured between perforated catheters inserted into the subcutaneous abdominal tissues of the dog and between perforated capsules implanted in the tissues 1 month previously. When the pressures in the catheters or perforated capsules were less than atmospheric pressure, the resistance to fluid movement was almost infinit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 89 1  شماره 

صفحات  -

تاریخ انتشار 2000