Separation of EMCL and IMCL in musculoskeletal 1H MR spectra by Filter-Diagonalization method (FDM)

نویسنده

  • J-M. Lin
چکیده

Introduction Measuring intramyocellular lipids (IMCL) in 1H MRS has been popular for its relation to insulin sensitivity, diabetes and obesity (1). However, quantification of IMCLs are often difficult because they are strongly overlapped with extramyocellular lipids (EMCL)(2, 3). The time domain algorithms offer many advantages for the quantification for separating IMCL and EMCL (1,4). First, the time domain methods usually require shorter signals but still exert high spectral resolution (5). Second, background contamination of macromolecules should be minimized, while the background accommodation can be done much easier in time domain (6). Among all the time-domain fitting methods, the Filter-Diagonalization Method (FDM) is a frequency-selective time domain method (7), which has several superior properties compared with other time-domain fitting methods. First, the fitting can be focused on a narrow frequency range other than whole spectral range. Second, its computation loading is lower than other singular value decomposition (SVD) based time-domain methods. Last year, we have demonstrated that FDM can successfully quantify three major metabolites on in vivo MRS of brain. We found that FDM perform well in extracting singlets other than multiplets even when the peaks are closely overlapped. In this preliminary study, we investigate the possibility of FDM to separate of EMCL and IMCL on in vivo MRS of muscle since lipid metabolites often have better signal to noise ratio and show simple spectra l singlet. Theory and Method The MRS time domain signals are modeled as sum of exponential decays: x(n)=Σdkuk+wn, where uk and dk are pole (chemical shift frequency and T2*) and amplitude (magnitude and phase) of k-th metabolite resonance; and wn is the noise. The signals x(n) form large Hankel matrices X0 and X1. Then the large X0 and X1 matrices are multiplied by the short time Fourier matrix F forming the U0 and U1: U0=F X0 F , U1=F X1 F T (where T is matrix transposition) Here the F matrix can focus the solution inside the basis. The eigenvalues{α/β} of the generalized eigenvalue equation β U1 V= α U0 V are signal poles uk. The amplitudes dk s, are derived from normalized eigenvectors: dk=[(FX01)Vk] 2 (the k represents the k-th column). Data Acquisition and Processing: The single voxel spectrum was acquired on a 3T system (Trio, Siemens Medical Solutions, Erlangen, Germany) with scan parameters: TR=1500ms, TE=35ms, NEX=64, VOI=15x15x20mm. Voxel was located at a healthy subject’s calf. The build-in PRESS sequence with automatic shimming was used. The FDM algorithm was written by c++ language on a Linux 32-bit PC, with external netlib's LAPACK, BLAS (basic linear algebra subroutine) library, and IT++ library (patched to use the zggevx subroutine). Only the first 200 points were used for processing. No zerofilling, apodization, or noise suppression was performed before the FDM processing. The F matrix is constructed by 2 narrow band basis, chosen to find the EMCL’s and IMCL’s ethyl groups, centered at 1.49ppm and 1.28ppm (8) with 0.05ppm in width. The complex generalized eigenproblem is solved by LAPACK’s zggevx subroutine. The amplifying eigenvalues (|{α/β}| > 1) arisen from the numerical errors are deleted. The total processing time is within several milliseconds. Results and Dicussion Figure 1 shows the fitting results a) raw spectrum, b) the fitted spectrum using FDM, c) the decomposed EMCL and IMCL component, d) the residues of spectrum. Arrows indicate the basis at 1.3 ppm and 1.5 ppm(red-boxed region). The CH2 groups of EMCL (EMCL_CH2)and IMCL(IMCL_CH2) are located inside the basis. We found the FDM can well separate the EMCL and IMCL peaks. (Figure 1c) The basis we choose can extract the poles inside the interested region, while suppressed the poles outside. Therefore, the quantification of EMCL or IMCL is immune from outside metabolites contamination. Several requirements have to be satisfied to successfully use FDM. First, spectra have better to be gathered in global homogenous field to full-filled the time domain exponential model. Second, the peaks have better to be located at the center of basis to prevent the distortion occurring at the edge of basis. In this study, we incorporate the frequency information of EMCL_CH2 and IMCL_CH2. Third, the SVD could be included into the algorithm to improve its stability. Fourth, the signal to noise ratio (SNR) and spectral bandwidth should be high enough. In this work, the data has only 64 averages; sampling frequency is only 1kHz. Higher quality spectra with more average and wider bandwidth should be obtained before we can quantify the small methyl groups (EMCL_CH3 and IMCL_CH3)(2). In summary, our preliminary result shows the FDM can reliably resolve the overlapping peaks. Performance of FDM should be studied by collecting more data set. The FDM may be useful not only as a preprocessing method but also as a tool directly quantifying the metabolites. In the future we will further investigate the FDM on the non-water suppressed muscular MRS where water signal can be extracted as an internal concentration reference for absolute quantification. Ackowledgement We thank the National Taiwan University Hospital for technical support on 3T MR system References

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-Resolution Echo-Planar Spectroscopic Imaging of the Human Calf

BACKGROUND This study exploits the speed benefits of echo-planar spectroscopic imaging (EPSI) to acquire lipid spectra of skeletal muscle. The main purpose was to develop a high-resolution EPSI technique for clinical MR scanner, to visualise the bulk magnetic susceptibility (BMS) shifts of extra-myocellular lipid (EMCL) spectral lines, and to investigate the feasibility of this method for the a...

متن کامل

Assessment of lipids in skeletal muscle by LCModel and AMARES.

PURPOSE To process single voxel spectra of the human skeletal muscle by using an advanced method for accurate, robust, and efficient spectral fitting (AMARES) and by linear combination of model spectra (LCModel). To determine absolute concentrations of extra- (EMCL) and intramyocellular lipids (IMCL). MATERIALS AND METHODS Single-voxel proton magnetic resonance spectroscopy (PRESS) was used t...

متن کامل

Processing of high resolution magic angle spinning spectra of breast cancer cells by the filter diagonalization method.

Proton nuclear magnetic resonance ((1)H NMR) spectroscopy for detection of biochemical changes in biological samples is a successful technique. However, the achieved NMR resolution is not sufficiently high when the analysis is performed with intact cells. To improve spectral resolution, high resolution magic angle spinning (HR-MAS) is used and the broad signals are separated by a T(2) filter ba...

متن کامل

Diffusion-weighted magnetic resonance spectroscopy: a novel approach to investigate intramyocellular lipids.

Motivated by the potential difference between intramyocellular lipid (IMCL) and extramyocellular lipid (EMCL) in their microscopically restricted diffusion environments, proton diffusion properties in IMCL and EMCL were characterized by diffusion-weighted magnetic resonance spectroscopy. Ex vivo experiments were conducted on fresh pig lower hindlimb muscle samples. In vivo experiments were perf...

متن کامل

Lipid storage changes in human skeletal muscle during detraining

UNLABELLED Exercise training is known to increase intramuscular triglyceride content in both trained and untrained legs. The purpose of the study was to determine the changes of intramyocellular lipids (IMCL) and extramyocellular lipids (EMCL) of both trained and untrained legs during detraining. We measured both IMCL and EMCL levels in previously trained vs. untrained legs during 4-weeks of de...