The cementless Vektor stem used in total hip arthroplasty
نویسندگان
چکیده
The cementless Vektor hip prosthesis stem is made of a special titanium alloy (TiAI6Nb7), and has a three-dimensional conus and an optimal proximal anchoring property. The aim of this prospective study was to scrutinise the first clinical and radiographical experiences of this stem used in 206 total hip replacements. The mean age of the patients including 126 women and 80 men was 54.6 years (range, 22.5-77.7 years). The mean follow-up time was 2.8 years (range, 1-5 years). The Merle d'Aubigné score improved from 9.3 to 17.1. A distal cortical hypertrophy was found twice, an atrophy of the proximal femur in 6 cases, and progressive radiolucent lines in one case. Two subfascial hematomas, two single dislocations, and two recurrent dislocations of the hip prosthesis, four lesions of the sciatic nerve (one persisting), two deep venous thrombosis, two pneumonias, and one lethal pulmonary embolism were detected. A stable proximal fixation was achieved in 95.6 % of the cases. Compared with other THA stems with a proximal anchorage, the outcome was improved with the Vektor stem.
منابع مشابه
Cementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report
Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...
متن کاملTotal Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry
Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...
متن کاملTotal Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population
Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...
متن کاملCementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs
Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...
متن کاملFixation of an Anatomically Designed Cementless Stem in Total Hip Arthroplasty
Purpose. The Anatomic Fiber Metal plus stem (Zimmer) is one of the anatomically designed cementless stems to achieve stable fixation by metaphyseal fit. We studied outcomes of cementless total hip arthroplasty using this stem and possible effects of metaphyseal fit on outcomes. Methods. The cementless total hip arthroplasty using this stem was performed for 155 hips. One hundred and thirty-seve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002