A sensitive method for cadmium determination using an on-line polyurethane foam preconcentration system and thermospray flame furnace atomic absorption spectrometry.

نویسندگان

  • César Ricardo Teixeira Tarley
  • Marco Aurélio Zezzi Arruda
چکیده

A new sensitive and low cost method for cadmium determination at microg l(-1) levels that combines an on-line preconcentration system with the thermospray flame furnace atomic absorption spectrometry technique (TS-FF-AAS) is described in this work. Cadmium is preconcentrated from an acidic medium (pH 2.0) by forming a complex with ammonium O,O-diethyldithiophosphate (DDTP), which is then adsorbed onto polyurethane foam (PUF). The elution step is performed by using 80% (v/v) ethanol. The effects of the chemical and flow variables associated with the preconcentration were studied, such as the pH of formation of the Cd-DDTP complex, the DDTP concentration, the preconcentration and elution flow rate and the mass of adsorbent. The present method was operated in volume-mode (2 ml) and provided a linear range from 0.4 to 15.0 microg l(-1) with a sample throughput of 16 h(-1). The increase of power detection related to TS-FF-AAS by coupling the preconcentration system was confirmed by the enhancement of sensitivity (ca. 5 times), when compared to the value for TS-FF-AAS alone, thus achieving a low detection limit (0.12 microg l(-1)). The accuracy of the method was confirmed from analyses of spiked water samples and by the use of a reference technique (ETAAS). Certified biological materials were also used for the same purpose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flotation/magnetic stirring-assisted liquid-liquid microextraction combined with flame atomic absorption spectrometry for the preconcentration and determination of cadmium (II) after optimization using experimental design

Arapid, highly sensitive and efficient flotation/magnetic stirring-assisted liquid-liquid microextraction combined with flame atomic absorption spectrometry has been proposed for the preconcentration and quantitative analysis of trace amounts of cadmium (II) in the presence of sodium diethyldithiocarbamateas complexingagent. Parameters including sample pH, concentration of the complexingagent, ...

متن کامل

Thermospray flame furnace-AAS determination of copper after on-line sorbent preconcentration using a system optimized by experimental designs.

The present paper describes the on-line coupling of a flow-injection system to a new technique, thermospray flame furnace-AAS (TS-FF-AAS), for the preconcentration and determination of copper in water samples. Copper was preconcentrated onto polyurethane foam (PUF) complexed with ammonium O,O-diethyldithiophosphate (DDTP), while elution was performed using 80% (v/v) ethanol. An experimental des...

متن کامل

Gallium trace on-line preconcentration/separation and determination using a polyurethane foam mini-column and flame atomic absorption spectrometry. Application in aluminum alloys, natural waters and urine.

A sensitive and selective flow injection time-based method for on-line preconcentration/separation and determination of gallium by flame atomic absorption spectrometry at trace levels was developed. The on-line formed gallium chloride complex is sorbed onto a polyether-type polyurethane foam mini-column, followed by on-line quantitative elution with isobutyl methyl ketone and direct introductio...

متن کامل

On-line preconcentration and determination of copper, lead and chromium(VI) using unloaded polyurethane foam packed column by flame atomic absorption spectrometry in natural waters and biological samples.

A simple, sensitive and low cost, flow injection time-based method was developed for on-line preconcentration and determination of copper, lead and chromium(VI) at sub mug l(-1) levels in natural waters and biological samples. At the optimum pH, the on-line formed metal-ammonium pyrrolidine dithiocarbamate (APDC) complexes were sorbed on the unloaded commercial polyurethane foam (PUF), and subs...

متن کامل

Use of factorial design and Doehlert matrix for multivariate optimisation of an on-line preconcentration system for lead determination by flame atomic absorption spectrometry.

A system for on-line preconcentration and determination of lead by flame atomic absorption spectrometry (FAAS) was proposed. It was based on the sorption of lead(II) ions on a minicolumn of polyurethane foam loaded with 2-(2-thiazolylazo)-5-dimethylaminophenol (TAM). The optimisation step was carried out using two-level full factorial and Doehlert designs for the determination of the optimum co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 20 6  شماره 

صفحات  -

تاریخ انتشار 2004