Shaping ability of ProTaper NEXT and BT-RaCe nickel-titanium instruments in severely curved root canals.

نویسندگان

  • S Bürklein
  • D Mathey
  • E Schäfer
چکیده

AIM To compare the shaping ability of four different nickel-titanium rotary instruments during the preparation of curved root canals in extracted teeth. METHODOLOGY A total of 80 root canals with curvatures ranging between 25° and 39° were divided into four groups of 20 canals. Based on radiographs taken prior to instrumentation, the groups were balanced with respect to the angle and the radius of canal curvature. Canals were prepared to a final apical size of 40 using Mtwo, ProTaper Universal, ProTaper NEXT and BT-RaCe. Using pre- and post-instrumentation radiographs, straightening of the canal curvatures and canal transportation were determined with a computer image analysis programme. Preparation time and instrument failures were also recorded. The data were analysed statistically using anova and Student-Newman-Keuls test. RESULTS The use of BT-RaCe files resulted in significantly more straightening during instrumentation compared to Mtwo (P < 0.05), whilst the differences between all other instruments were not significant (P > 0.05). No significant differences were obtained between all four instruments regarding canal transportation (P = 0.429). Instrumentation with ProTaper NEXT files was significantly faster than with all other instruments (P < 0.05). During the preparation of the curved canals, one BT2 instrument fractured, whilst no fracture occurred when using the other instruments (P > 0.05). CONCLUSIONS Within the parameters of this study, all instruments maintained root canal curvature well and were safe. However, care should be taken when using the BT2 instrument due to its unique cylindrical design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the shaping ability of RaCe, FlexMaster, and ProFile nickel-titanium instruments in severely curved root canals

BACKGROUND This in vitro study compared the shaping ability of RaCe, FlexMaster, and ProFile rotary nickel-titanium instruments in severely curved root canals of extracted teeth. MATERIAL AND METHODS Sixty maxillary molars with curvatures ranging from 25° to 65° were embedded in a muffle system and portioned into five horizontal sections (thickness 1.2 mm), starting from the apex. Canals were...

متن کامل

Comparison of Shaping Ability of Five Nickel-Titanium Rotary Instruments in Simulated Curved Canals

This study compared the shaping ability of five Ni-Ti rotary files (ProTaper Universal, Reciproc, Hyflex CM, ProTaper Next and TF Adaptive) in simulated root canals. Each group consisted of 10 root canals. Preand post-instrumentation photographs were taken using a precise camera and superimposed with Photoshop. Material removal from the inner and outer canal walls, transportation and centering ...

متن کامل

Comparison of the shaping characteristics of Neolix and Protaper Universal systems in preparation of severely-curved simulated canals

BACKGROUND The aim of this in vitro study was to compare the shaping characteristics of two types of nickel-titanium endodontic file systems with regard to the following parameters: Canal straightening, Canal deviation and Instrumentation time. MATERIAL AND METHODS Fifty severely curved canals simulated in resin blocks were prepared to an apical size 25 using Protaper Universal orNeolix syste...

متن کامل

Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instruments. Part 2. Cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth.

AIM To compare the cleaning effectiveness and shaping ability of Mtwo, K3, and RaCe nickel-titanium rotary instruments during the preparation of curved root canals in extracted human teeth. METHODOLOGY A total of 60 root canals of mandibular and maxillary molars with curvatures ranging between 25 degrees and 35 degrees were divided into three groups of 20 canals. Based on radiographs taken pr...

متن کامل

Cyclic fatigue resistance of two nickel-titanium instruments in different curving angles: a comparative study.

The cyclic resistance of ProTaper Universal (size 25/08) and ProTaper Next (size 25/06) instruments was compared in artificial canals with different curvatures in this study. A total of 30 ProTaper Universal and 30 ProTaper Next instruments were divided into 6 groups (n = 10) and were operated into artificial canals with 3 different angles of curvature (45°, 60°, 90°). The canal length was kept...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International endodontic journal

دوره 48 8  شماره 

صفحات  -

تاریخ انتشار 2015