Micro-field evoked potentials recorded from the porcine sub-dural cortical surface utilizing a microelectrode array.
نویسندگان
چکیده
A sub-dural surface microelectrode array designed to detect micro-field evoked potentials has been developed. The device is comprised of an array of 350-microm square gold contacts, with bidirectional spacing of 150 microm, contained within a polyimide Kapton material. Cytotoxicity testing suggests that the device is suitable for use with animal and human patients. Implementation of the device in animal studies revealed that reliable evoked potentials could be acquired. Further work will be needed to determine how these micro-field potentials, which demonstrate selectivity for one eye, relate to the distribution of the ocular dominance columns of the occipital cortex.
منابع مشابه
Efficacy and reliability of long-term implantation of multi-channel microelectrode arrays in the optical nerve sheath of rabbit eyes
In addition to epiretinal and subretinal areas, the optic nerve (ON) is also a candidate location for implanting visual prosthesis to restore vision of patients with retinitis pigmentosa (RP). Since the ON receives all the signals from the retina, stimulating the ON may potentially evoke phosphenes over a wider range of visual field. In this study, we designed a 9-channel microelectrode array a...
متن کاملFabrication and testing of microelectrodes for small-field cortical surface recordings.
A microfabrication approach to produce a microelectrode array that is suitable for use with human patients has been developed. The device is comprised of materials that are consistent with those of clinically used macroelectrodes (platinum electrode contacts suspended within a biomedical grade polydimethylsiloxane, PDMS). Photolithography, metal deposition, wire bonding, and PDMS encapsulation ...
متن کاملCerebral cortical respiratory-related evoked potentials elicited by inspiratory occlusion in lambs.
Respiratory-related evoked potentials (RREP) elicited by inspiratory mechanical loads have been recorded in humans. Early RREP peaks were hypothesized to be generated by activation of neurons in the somatosensory cortex. An animal model was developed to test this hypothesis in chronically instrumented, awake, spontaneously breathing lambs. Electrocorticogram (ECoG) was recorded bilaterally with...
متن کاملAction potential recording from dielectrophoretically positioned neurons inside micro-wells of a planar microelectrode array.
To organise in vitro neural networks at the cellular level and study their electrical patterns, we have fabricated 4 x 4 planar microelectrode arrays using conventional photolithography. The electrode sites of these arrays are located inside micro-wells, for confining the neurons, which are connected with neighbouring wells via micro-trenches capable of guiding the outgrowth of neurites. In ord...
متن کاملHigh-frequency EEG covaries with spike burst patterns detected in cortical neurons.
Invasive microelectrode recordings measure neuronal spikes, which are commonly considered inaccessible through standard surface electroencephalogram (EEG). Yet high-frequency EEG potentials (hf-EEG, f > 400 Hz) found in somatosensory evoked potentials of primates may reflect the mean population spike responses of coactivated cortical neurons. Since cortical responses to electrical nerve stimula...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of neuroscience methods
دوره 162 1-2 شماره
صفحات -
تاریخ انتشار 2007