Enhancing the performance of the light field microscope using wavefront coding.

نویسندگان

  • Noy Cohen
  • Samuel Yang
  • Aaron Andalman
  • Michael Broxton
  • Logan Grosenick
  • Karl Deisseroth
  • Mark Horowitz
  • Marc Levoy
چکیده

Light field microscopy has been proposed as a new high-speed volumetric computational imaging method that enables reconstruction of 3-D volumes from captured projections of the 4-D light field. Recently, a detailed physical optics model of the light field microscope has been derived, which led to the development of a deconvolution algorithm that reconstructs 3-D volumes with high spatial resolution. However, the spatial resolution of the reconstructions has been shown to be non-uniform across depth, with some z planes showing high resolution and others, particularly at the center of the imaged volume, showing very low resolution. In this paper, we enhance the performance of the light field microscope using wavefront coding techniques. By including phase masks in the optical path of the microscope we are able to address this non-uniform resolution limitation. We have also found that superior control over the performance of the light field microscope can be achieved by using two phase masks rather than one, placed at the objective's back focal plane and at the microscope's native image plane. We present an extended optical model for our wavefront coded light field microscope and develop a performance metric based on Fisher information, which we use to choose adequate phase masks parameters. We validate our approach using both simulated data and experimental resolution measurements of a USAF 1951 resolution target; and demonstrate the utility for biological applications with in vivo volumetric calcium imaging of larval zebrafish brain.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Instantaneous three-dimensional sensing using spatial light modulator illumination with extended depth of field imaging.

Imaging three-dimensional structures represents a major challenge for conventional microscopies. Here we describe a Spatial Light Modulator (SLM) microscope that can simultaneously address and image multiple targets in three dimensions. A wavefront coding element and computational image processing enables extended depth-of-field imaging. High-resolution, multi-site three-dimensional targeting a...

متن کامل

Reducing depth induced spherical aberration in 3D widefield fluorescence microscopy by wavefront coding using the SQUBIC phase mask

Imaging thick biological samples introduces spherical aberration (SA) due to refractive index (RI) mismatch between specimen and imaging lens immersion medium. SA increases with the increase of either depth or RI mismatch. Therefore, it is difficult to find a static compensator for SA. Different wavefront coding methods have been studied to find an optimal way of static wavefront correction to ...

متن کامل

Decomposition of the OTF: Wavefront Coding as a Cornu Spiral

Recent years have witnessed the development of a new imaging technique, known as wavefront coding, that employs an aspherical phase mask and post-detection electronic processing to enable high-performance imaging with far greater tolerance to defocus aberration than traditional optical imaging [1]. Various methods have been employed for synthesizing the design of wavefront-coding phase mask [1,...

متن کامل

Wavefront Coding for Athermalization of Infrared Imaging Systems

Wavefront coding involves the insertion of an asymmetric refractive mask close to the pupil plane of an imaging system so as to encode the image with a specific point spread function that, when combined with decoding of the recorded image, can enable greatly reduced sensitivity to imaging aberrations. The application of wavefront coding has potential in the fields of microscopy, where increased...

متن کامل

Adaptive optics widefield microscope corrections using a MEMS DM and Shack-Hartmann wavefront sensor

We demonstrated the used of an adaptive optic system in biological imaging to improve the imaging characteristics of a wide field microscope. A crimson red fluorescent bead emitting light at 650 nm was used together with a ShackHartmann wavefront sensor and deformable mirror to compensate for the aberrations introduce by a Drosophila embryo. The measurement and correction at one wavelength impr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics express

دوره 22 20  شماره 

صفحات  -