Changes of Atrial Natriuretic Peptides after Defibrillation Threshold Testing Predicted Future Ventricular Arrhythmia Event.

نویسندگان

  • Po-Ching Chi
  • Jen-Yuan Kuo
  • Chun-Yen Chen
  • An-Mei Wang
  • Chung-Lieh Hung
  • Sheng-Hsiung Chang
  • Bing-Fu Shih
  • Hung-I Yeh
چکیده

BACKGROUND We investigated the change of natriuretic peptides during defibrillation threshold (DFT) testing and its relationship with future ventricular arrhythmia (VA) events in patients implanted with an implantable cardioverter defibrillator (ICD). METHODS Atrial natriuretic peptide (ANP), brain natriuretic peptide (BNP), and c-type natriuretic peptide (CNP) were measured in 21 patients (mean age 61 ± 13 years; 67% male) undergoing ICD implantation. Blood samples of the patients were drawn at pre-implantation, 30 minutes, 60 minutes, and 24 hours after DFT testing. The patients were followed and divided into two groups according to the occurrence of VA in 18 months. The biomarker levels and their changes were compared in patients with and without further VA. RESULTS The pre-implantation ANP levels were higher at pre-implantation and increased significantly at 30 minutes after DFT testing (Δ30minANP) among patients with VA events. The BNP and CNP levels did not change significantly after DFT testing in both groups. The area under curve was 0.82 for the change in Δ30minANP determining further ventricular events. The optimal Δ30minANP cutoff value was 0.51 pg/ml, with sensitivity of 0.83 and specificity of 0.68. Multivariable analysis confirmed that patients with Δ30minANP more than 0.51 pg/ml have a higher risk of further ventricular events (hazard ratio 39.8, 95% confidence interval: 2.87-553.01, p = 0.006). The pre-implantation ANP level could not predict future VA events (hazard ratio 1.06, 95% CI: 1.00-1.14, p = 0.06). CONCLUSIONS The increase of ANP concentration after DFT testing predicted future VA events after ICD implantation while the BNP and CNP levels did not predict future VA events.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Atrioverter: an implantable device for the treatment of atrial fibrillation.

BACKGROUND During atrial fibrillation, electrophysiological changes occur in atrial tissue that favor the maintenance of the arrhythmia and facilitate recurrence after conversion to sinus rhythm. An implantable defibrillator connected to right atrial and coronary sinus defibrillation leads allows prompt restoration of sinus rhythm by a low-energy shock. The safety and efficacy of this system, c...

متن کامل

Current approaches and future developments in automatic tachycardia detection and diagnosis.

Implantable automatic cardioverter/defibrillators are now commonly used to treat malignant ventricular arrhythmias.' Early models simply detected a rapid heart rate and delivered a defibrillation shock, but more modem devices can deliver treatment as a tiered strategy of antitachycardia pacing, synchronised low energy cardioversion, and high energy defibrillation.2' Accurate detection and diagn...

متن کامل

Effect of duration of ventricular fibrillation on defibrillation efficacy in humans.

The currently available automatic implantable cardioverter-defibrillator has proven highly successful for termination of ventricular tachycardia and fibrillation. Newer devices, however, permit lower energy shocks to be delivered initially and longer episodes of arrhythmia to occur before shocks are delivered. These changes may result in longer durations of arrhythmia before successful terminat...

متن کامل

Effect of Duration of Ventricular Fibrillation

The currently available automatic implantable cardioverter-defibrillator has proven highly successful for termination of ventricular tachycardia and fibrillation. Newer devices, however, permit lower energy shocks to be delivered initially and longer episodes of arrhythmia to occur before shocks are delivered. These changes may result in longer durations of arrhythmia before successful terminat...

متن کامل

The effect of newer antiarrhythmic drugs on defibrillation threshold.

This study was conducted to determine the effects of clofilium phosphate and bretylium tosylate on ventricular defibrillation threshold. Dogs were anesthetized with pentobarbital and subjected to repeated fibrillation-defibrillation episodes. Defibrillation thresholds were determined at 15-min intervals, using underdamped 5--6 msec sinusoidal current shocks, from 30 min before drug injection to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Acta Cardiologica Sinica

دوره 33 4  شماره 

صفحات  -

تاریخ انتشار 2017