Urinary screening tests to detect excessive lead absorption.

نویسنده

  • R W Ellis
چکیده

The biological variation encountered in spot urine samples was assessed by collecting six sets of serial urine specimens from five men. The lead, coproporphyrin, and creatinine contents of each specimen were determined and the specific gravity was measured. It is found that as the mean concentration of the metabolite rises so the variability of the individual values increases. The scatter of the concentrations is not significantly different from that found in the rates of excretion. Adjustment of the figures to either a constant specific gravity or creatinine concentration increased the scatter. The effect of the diurnal cycle on the variability is negligible as the spread of the combined results is uniform over the 24-hour period. The results of spot urine samples must be considered collectively before they can indicate the mean excretion level. Twenty-four-hour urine samples were obtained from 23 lead-intoxicated men before and throughout their treatment with chelating agents. The initial excretion of lead during intravenous infusion of disodium calcium ethylenediaminetetra-acetate (first Pb EDTA) and the weight of lead excreted as the complex, before the coproporphyrin excretion faUs to a normal level (less than ioo ,tg. per day), termed the 'excess' lead, are used as objective measures of the lead absorption. These two indices are linearly related to the pretreatment urinary levels of lead and coproporphyrin, regardless of whether the results are expressed in ,ug. per litre or ,ug. per day. Due to the environment having an effect on the urinary concentrations it is concluded that in general the weight of metabolite excreted in the 24-hour period possibly provides the more reliable guide to the lead absorption of the individual.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recognition and management of children with increased lead absorption.

Childhood lead poisoning has been increasingly recognised in the USA where large-scale screening programmes detect some 40 000 cases of undue lead absorption a year. This contrasts with data from the UK where about 100 cases are recognised each year. The situation in other countries is largely unknown, although small surveys have revealed cases from a wide variety of sources. These apparent dis...

متن کامل

An investigation of lead absorption in an electric accumulator factory with the use of personal samplers.

Williams, M. K., King, E., and Walford, Joan (1969). Brit. J. industr. Med., 26, 202-216. An investigation of lead absorption in an electric accumulator factory with the use of personal samplers. Thirty-nine lead workers and controls, in stable conditions of exposure, each wore personal lead-in-air samplers daily for two weeks. During the second week samples for blood lead, urinary lead, urinar...

متن کامل

An Early Sign of Lead Poisoning.

In the New England Journal of Medicine of October 10, 1963 an article by N. Sonkin described Retinal Stippling -a New Physical Sign in the Early Diagnosis of Lead Poisoning. In this paper Sonkin described stippling around the optic disc which consisted of glistening grey discrete spots that he considered to be lead pigment. This was noted to be present in eight men who had been mixing various l...

متن کامل

Evaluation of the leukocyte esterase and nitrite urine dipstick screening tests for detection of bacteriuria in women with suspected uncomplicated urinary tract infections.

A positive dipstick urinalysis (i.e., leukocyte esterase test and/or nitrite test) did not reliably detect significant bacteriuria in 479 ambulatory women with suspected uncomplicated urinary tract infection; 18.9% of the urine samples that demonstrated significant bacteriuria would have been rejected by the laboratory based on a negative urinalysis screen.

متن کامل

A comparison of costs of universal versus targeted lead screening for young children.

The purposes of this study were to compare universal blood lead screening for young children versus targeting by a risk assessment questionnaire and to examine the cost implications of each approach. Costs reflect the total number of blood tests required and cost of specimen collection, handling, and testing per elevated case. The setting included the metropolitan areas of Minneapolis and St. P...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of industrial medicine

دوره 23 4  شماره 

صفحات  -

تاریخ انتشار 1966