Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS.
نویسندگان
چکیده
In recent years, high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS/MS) detection has been demonstrated to be a powerful technique for the quantitative determination of drugs and metabolites in biological fluids. However, the common and early perception that utilization of HPLC-MS/MS practically guarantees selectivity is being challenged by a number of reported examples of lack of selectivity due to ion suppression or enhancement caused by the sample matrix and interferences from metabolites. In light of these serious method liabilities, questions about how to develop and validate reliable HPLC-MS/MS methods, especially for supporting long-term human pharmacokinetic studies, are being raised. The central issue is what experiments, in addition to the validation data usually provided for the conventional bioanalytical methods, need to be conducted to confirm HPLC-MS/MS assay selectivity and reliability. The current regulatory requirements include the need for the assessment and elimination of the matrix effect in the bioanalytical methods, but the experimental procedures necessary to assess the matrix effect are not detailed. Practical, experimental approaches for studying, identifying, and eliminating the effect of matrix on the results of quantitative analyses by HPLC-MS/MS are described in this paper. Using as an example a set of validation experiments performed for one of our investigational new drug candidates, the concepts of the quantitative assessment of the "absolute" versus "relative" matrix effect are introduced. In addition, experiments for the determination of, the "true" recovery of analytes using HPLC-MS/MS are described eliminating the uncertainty about the effect of matrix on the determination of this commonly measured method parameter. Determination of the matrix effect allows the assessment of the reliability and selectivity of an existing HPLC-MS/MS method. If the results of these studies are not satisfactory, the parameters determined may provide a guide to what changes in the method need to be made to improve assay selectivity. In addition, a direct comparison of the extent of the matrix effect using two different interfaces (a heated nebulizer, HN, and ion spray, ISP) under otherwise the same sample preparation and chromatographic conditions was made. It was demonstrated that, for the investigational drug under study, the matrix effect was clearly observed when ISP interface was utilized but it was absent when the HN interface was employed.
منابع مشابه
Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry
The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...
متن کاملSample Preparation and Extraction in Small Sample Volumes Suitable for Pediatric Clinical Studies: Challenges, Advances, and Experiences of a Bioanalytical HPLC-MS/MS Method Validation Using Enalapril and Enalaprilat
In USA and Europe, medicines agencies force the development of child-appropriate medications and intend to increase the availability of information on the pediatric use. This asks for bioanalytical methods which are able to deal with small sample volumes as the trial-related blood lost is very restricted in children. Broadly used HPLC-MS/MS, being able to cope with small volumes, is susceptible...
متن کاملValidation of bioanalytical LC-MS/MS assays: evaluation of matrix effects.
Liquid chromatography coupled to atmospheric pressure ionization tandem mass spectrometry is currently the method of choice for the quantitative determination of drugs in biological matrices. The advantages of this technique include high specificity, sensitivity and throughput. However, co-eluting matrix components, which are not observed in the chromatogram, can have a detrimental effect on th...
متن کاملQuantitative bioanalytical and analytical method development of dibenzazepine derivative, carbamazepine: A review☆
Bioanalytical methods are widely used for quantitative estimation of drugs and their metabolites in physiological matrices. These methods could be applied to studies in areas of human clinical pharmacology and toxicology. The major bioanalytical services are method development, method validation and sample analysis (method application). Various methods such as GC, LC-MS/MS, HPLC, HPTLC, micella...
متن کاملComparison of bioanalytical methods for the quantitation of PEGylated human insulin.
PURPOSE The quality of bioanalytical data is dependent upon selective, sensitive, and reproducible analytical methods. With evolving technologies available, bioanalytical scientists must assess which is most appropriate for their molecule through proper method validation. For an early stage PEGylated insulin program, the characteristics of four platforms, ELISA, ECL, Gyrolab, and LC-MS/MS, were...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 75 13 شماره
صفحات -
تاریخ انتشار 2003