A branching-tree lung phantom for hyperpolarized noble gas MRI
نویسندگان
چکیده
Introduction Hyperpolarized noble gas MRI is able to provide useful information related to structural and physiological properties of lungs and lung diseases. To relate the measured parameters (e.g. relaxation times, diffusion coefficients, flow rate) to lung properties (e.g. airway diameter, surface area, connectivity) several mathematical and computer models have been proposed [1-3]. Validation of these models has generally been done indirectly by comparison to known lung properties or histological sections. Direct comparison of computer simulations and measurements on a phantom built following the Kitaoka acinus model has been reported [3]. However, the geometry of this model significantly differs from the lung geometry (e.g. rectangular airway cross-section, square-angle branching). Similarly, different experimental methods and/or pulse sequences are used by different groups and their results are difficult to compare since they are performed in different subjects under different experimental conditions. In this work, we describe the construction of a simple branching-tree lung phantom made of commonly available parts that can be easily reproduced in any laboratory. Preliminary experimental results obtained with this phantom are reported, including dynamic ventilation imaging and diffusion measurements. Methods The phantom was built from polypropylene Y-connectors commercially available from Harvard Apparatus (Kent, UK). Figure 1 shows part of the phantom consisting of five generations with inner diameters ranging from 4–1.5 mm, which reproduce approximately generations 4 till 9 of Weibel’s lung model [4]. Other generations can also be modeled since a large range of Y-connectors with other diameters are readily available. Hyperpolarized helium of polarization about 25% was obtained using a Helispin polarizer (GE, USA). 2D (coronal projection image, TR/TE: 4.8/2.1 ms, 128x128, FOV: 20cm, flip angle: 7°), 3D (TR/TE: 5.3/1.4 ms, 100x100X100, FOV: 20cm, flip angle: 1°) and dynamic ventilation (series of 2D coronal projections with frame rate ~87 ms) images were obtained on a 1.5T GE HDx system using a spoiled gradient-echo sequence. Diffusion experiments were performed on a 3T Philips Intera system. Global ADC data was obtained from FID acquisition after bi-polar diffusion gradients. 1D diffusion profiles were obtained by adding a read-out gradient. For both sequences, the diffusion gradient timing parameters were similar to those used in [1], and the gradient strength was varied from 0 to 15 mT/m in 60 equal steps. Custom-built transmit-receive birdcage coils (15 cm diameter) were used. Results and Discussion Fig. 2 shows a reconstruction of a 3D He image obtained from the phantom. All five generations of the phantom can be clearly observed which proves the phantom can be used to assess the spatial resolution of the MR system and He imaging method down to 1 mm. Fig. 3 shows a series of images acquired during the injection of He in the phantom using a syringe to simulate the results of dynamic ventilation imaging during inhalation. The image series exhibits excellent temporal and spatial resolution. It can be observed how the gas reaches all five “airway” generations of the phantom. The global diffusion experiments resulted in an ADC value of 0.79 cm/s with the diffusion gradient in the Z direction (up-down direction in Fig. 3) and 0.70 cm/s with the gradient in Y direction (perpendicular to Fig. 3 plane), where more restriction is present. Fig. 4 shows the 1D diffusion-weighted profile of the phantom corresponding to the b=0 s/cm. The calculated ADC values for each of the peaks (locations) marked in the spectrum are presented in Table 1, which indicates the presence of different levels of diffusion restriction at these locations due to the presence of different airway dimensions and orientations. The volumeweighted average of these ADC values (0.73 cm/s) is in good agreement with the corresponding global ADC value reported above (0.70 cm/s). The phantom may also be useful in other diffusion measurements such as long range ADC, anisotropy and tortuosity. T2* effects can easily be simulated by submerging the phantom in water, since polypropylene fibers have been proven to be a good model for lung susceptibility effects [5]. The accurate knowledge of the dimensions and geometry of the phantom components and their spatial arrangement allows simulations to be easily constructed that exactly reproduce the phantom geometry and can be compared directly to experimental data. Conclusion The results obtained in this work demonstrate that this phantom is a valid physical model of the lung that can be used to validate the predictions of theoretical and numerical simulations in HNG MR imaging. The phantom may be very useful in the investigation between geometrical properties of the lung and measured MR parameters.
منابع مشابه
Hyperpolarized Noble Gas Mri of the Brain and Lungs
INTRODUCTION We are developing a new diagnostic technology: magnetic resonance imaging (MRI) and spectroscopy of hyperpolarized noble gases. Large non-equilibrium nuclear spin polarizations can be created in the spin-1/2 noble gases, He and Xe, using the technique of spin-exchange optical pumping. Such large polarizations greatly enhance the magnetic resonance detection of He and Xe, enabling h...
متن کاملSignal-to-noise ratio comparison of encoding methods for hyperpolarized noble gas MRI.
Some non-Fourier encoding methods such as wavelet and direct encoding use spatially localized bases. The spatial localization feature of these methods enables optimized encoding for improved spatial and temporal resolution during dynamically adaptive MR imaging. These spatially localized bases, however, have inherently reduced image signal-to-noise ratio compared with Fourier or Hadamad encodin...
متن کاملMRI of the lung gas-space at very low-field using hyperpolarized noble gases.
In hyperpolarized (HP) noble-gas magnetic resonance imaging, large nuclear spin polarizations, about 100,000 times that ordinarily obtainable at thermal equilibrium, are created in 3He and 129Xe. The enhanced signal that results can be employed in high-resolution MRI studies of void spaces such as in the lungs. In HP gas MRI the signal-to-noise ratio (SNR) depends only weakly on the static magn...
متن کاملHyperpolarized Noble Gas Magnetic Resonance Imaging
Introduction Hyperpolarized noble gas magnetic resonance imaging (HP gas MRI) is a new and innovative imaging method that has made it possible, for the first time, to obtain high resolution MR images of air-filled organs such as the lungs, as well as lipid rich tissue such as the brain. Unlike conventional MRI which relies on the detection of water protons in biological tissue, HP gas MRI is ba...
متن کاملNew insights into lung diseases using hyperpolarized gas MRI.
Hyperpolarized (HP) gases are a new class of contrast agents that permit to obtain high temporal and spatial resolution magnetic resonance images (MRI) of the lung airspaces. HP gas MRI has become important research tool not only for morphological and functional evaluation of normal pulmonary physiology but also for regional quantification of pathologic changes occurring in several lung disease...