Influence of bone and dental implant parameters on stress distribution in the mandible: a finite element study.
نویسندگان
چکیده
PURPOSE The complicated relationships between mandibular bone components and dental implants have attracted the attention of structural mechanics researchers as well as dental practitioners. Using the finite element method, the present study evaluated various bone and implant parameters for their influence on the distribution of von Mises stresses within the mandible. MATERIALS AND METHODS Various parameters were considered, including Young's modulus of cancellous bone, which varies from 1 to 4 GPa, and that of cortical bone, which is between 7 and 20 GPa. Implant length (7, 9, 11, 13, and 15 mm), implant diameter (3.5, 4.0, 4.5, and 5.5 mm), and cortical bone thickness (0.3 to 2.1 mm) were also considered as parameters. Assumptions made in the analysis were: modeling of the complex material and geometric properties of the bone and implant using two-dimensional triangular and quadrilateral plane strain elements, 50% osseointegration between bone and implant, and linear relationships between the stress value and Young's modulus of both cancellous and cortical bone at any specific point. RESULTS An increase in Young's modulus and a decrease in the cortical bone thickness resulted in elevated stresses within both cancellous and cortical bone. Increases in the implant length led to greater surface contact between the bone and implant, thereby reducing the magnitude of stress. CONCLUSIONS The applied masticatory force was demonstrated to be the most influential, in terms of differences between minimum and maximum stress values, versus all other parameters. Therefore loading should be considered of vital importance when planning implant placement.
منابع مشابه
Evaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method
longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...
متن کاملبررسی اثر ضخامت پوشش هیدروکسی آپاتیت بر توزیع تنش در اطراف سطح تماس ایمپلنت دندانی- استخوان با روش المان محدود
Background and Aims: Hydroxyapatite coating has allocated a special place in dentistry due to its biocompatibility and bioactivity. The purpose of this study was to evaluate the relation between the hydroxyapatite thickness and stress distribution by using finite element method. Materials and Methods: In this paper, the effect of hydroxyapatite coating thickness on dental implants was studi...
متن کاملEffect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis
Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...
متن کاملImmediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis
Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis Dr. A. Fazel * - Dr. SH. A. Alai ** - Dr. M. Rismanchian *** *Associate Professor of Prosthodontics Dept., Faculty of Dentistry and Dental Research Center, Tehran University / Medical Sciences. **Assistant Professor of Prosthodontics Dept., Faculty of...
متن کاملEffect of Abutment Angulation and Material on Stress and Strain Distributions in Premaxillary Bone: A Three-Dimensional Finite Element Analysis
Background and Aim: Dental implants with angled abutments are often inserted in the anterior maxillary region due to the status of the residual ridge and aesthetic considerations. The purpose of this study was to assess stress and strain distributions in the premaxillary bone around dental implants by means of finite element analysis (FEA). Materials and Methods: Four three-dimensional (3D) fi...
متن کاملتعیین توزیع تنش و کرنش استخوان اطراف ایمپلنت در طرح All-on-4 به روش آنالیز اجزای محدود
Background and Aims: The All-on-4 design with its significant advantages is an appropriate model in reconstruction of edentulous mandible. Evaluation of stress and strain distribution in this model is necessary for better judgment. The purpose of this FEA study was to measure stress and strain distribution on peri-implant bone in All-on-4 design in edentulous mandible. Materials and Methods: Th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 24 5 شماره
صفحات -
تاریخ انتشار 2009