Lung Function Monitoring; A Randomized Agreement Study

نویسندگان

  • Sveinung Berntsen
  • Solvor B. Stølevik
  • Petter Mowinckel
  • Wenche Nystad
  • Trine Stensrud
چکیده

OBJECTIVE To determine the agreement between devices and repeatability within devices of the forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), peak expiratory flow (PEF) and forced expiratory flow at 50% of FVC (FEF50) values measured using the four spirometers included in the study. METHODS 50 (24 women) participants (20-64 years of age) completed maximum forced expiratory flow manoeuvres and measurements were performed using the following devices: MasterScreen, SensorMedics, Oxycon Pro and SpiroUSB. The order of the instruments tested was randomized and blinded for both the participants and the technicians. Re-testing was conducted on a following day within 72 hours at the same time of the day. RESULTS The devices which obtained the most comparable values for all lung function variables were SensorMedics and Oxycon Pro, and MasterScreen and SpiroUSB. For FEV1, mean difference was 0.04 L (95% confidence interval; -0.05, 0.14) and 0.00 L (-0.06, 0.06), respectively. When using the criterion of FVC and FEV1 ≤ 0.150 L for acceptable repeatability, 67% of the comparisons of the measured lung function values obtained by the four devices were acceptable. Overall, Oxycon Pro obtained most frequently values of the lung function variables with highest precision as indicated by the coefficients of repeatability (CR), followed by MasterScreen, SensorMedics and SpiroUSB (e.g. min-max CR for FEV1; 0.27-0.46). CONCLUSION The present study confirms that measurements obtained by the same device at different times can be compared; however, measured lung function values may differ depending on spirometers used.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Do Statins Improve Lung Function in Asthmatic Patients? A Randomized and Double-Blind Trial

      There are evidences that statins have anti-inflammatory effects beyond their cholesterol lowering properties. The study was conducted to assess the effects of atorvastatin on asthma as an inflammatory disease. Patients with moderate to severe asthma were entered this randomized, double blind, crossover clinical trial. The impact of oral atorvastatin (10 mg/day) on the lung function of nor...

متن کامل

A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia

Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is u...

متن کامل

The accuracy of FEF25-75/ FVC for primary classification of the pulmonary function test

Introduction: The forced expiratory flow at 25 and 75% of the pulmonary volume/forced vital capacity ratio (FEF25-75/FVC) as a spirometry parameter has been successful in the early diagnosis of chronic obstructive pulmonary disease (COPD) and the methacholine challenge test for assessing airway responsiveness.To determine the accuracy of FEF25-7...

متن کامل

Does a minimally invasive approach result in better pulmonary function postoperatively when compared with median sternotomy for coronary artery bypass graft?

A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was 'Does a minimally invasive approach result in better pulmonary function postoperatively when compared with median sternotomy for coronary artery bypass graft?'. Procedures such as limited sternotomy and minimally invasive direct coronary artery bypass (MIDCAB) though a minithoraco...

متن کامل

Reduced Lung Function and Progression to Prediabetes: A Prospective Study

Objective: Prediabetes is a state that people have blood glucose levels higher than normal but still not in diabetes range. There is a close relationship between impaired lung function and diabetes mellitus (DM). Reduced lung function can be present before the clinical evidence of diabetes or insulin resistance. Materials and Methods: The total number of subjects in this longitudinal study was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016