A time-response model for analysis of drug transport and blood flow response during iontophoresis of acetylcholine and sodium nitroprusside.

نویسندگان

  • Erik Tesselaar
  • Joakim Henricson
  • Susanne Jonsson
  • Folke Sjöberg
چکیده

BACKGROUND/AIMS The analysis of blood flow responses to iontophoresis of vasoactive drugs is often limited to evaluation of maximum responses. In this study, a time-response model is proposed for the blood flow responses to vasoactive drugs applied by iontophoresis. METHODS The microvascular bed is represented as a single compartment with a zero-order influx of the drugs from the electrode and a first-order clearance due to diffusion and blood flow. The blood flow response to the local drug dose is described using the E(max) model. RESULTS The model accurately describes the blood flow responses to acetylcholine and sodium nitroprusside during a single iontophoretic current pulse. There is a significant clearance out of the microvascular bed during iontophoresis which depends on the type of drug administered. CONCLUSION The model enables an accurate estimation of response parameters such as ED50 and maximum response, even if the true maximum blood flow is not obtained. The results suggest that due to clearance from the microvascular bed, the local drug dose during a single pulse of current is not linearly proportional to current strength multiplied by pulse duration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microvascular involvement in systemic sclerosis: laser Doppler evaluation of reactivity to acetylcholine and sodium nitroprusside by iontophoresis.

OBJECTIVES To investigate the skin vasodilatory response to iontophoretically applied acetylcholine (Ach), an endothelium dependent vasodilator, and to sodium nitroprusside (SNP), an endothelium independent vasodilator, in patients with systemic sclerosis (SSc). METHODS Eleven SSc patients were preliminarily studied (10 females, mean age 40.5; mean disease duration 6.5 years), and 16 age and ...

متن کامل

Dynamic Response Analysis of the Planar and Tubular Solid Oxide Fuel Cells to the Inlet Air Mass Flow Rate Variation

The purpose of present study is to investigate the dynamic response of two conventional types of solid oxide fuel cells to the inlet air mass flow rate variation. A dynamic compartmental model based on CFD principles is developed for two typical planar and tubular SOFC designs. The model accounts for transport processes (heat and mass transfer), diffusion processes, electrochemical processes, a...

متن کامل

Influence of vehicle resistance on transdermal iontophoretic delivery of acetylcholine and sodium nitroprusside in humans.

Iontophoresis is a valuable method of noninvasive drug delivery for assessment of skin microvascular function, but it is important to consider and minimize its potential nonspecific electrical effects on blood flow. The use of sodium chloride (NaCl) instead of water as the iontophoresis vehicle has been reported to reduce these effects because it has a lower electrical resistance. However, this...

متن کامل

Tissue viability imaging: microvascular response to vasoactive drugs induced by iontophoresis.

When one is studying the physiology of the cutaneous microcirculation there is a need for relevant non-invasive and versatile techniques. In this study we used a new optical device, the tissue viability imager (TiVi), to map changes in cutaneous microvascular concentrations of red blood cells during iontophoresis of vasoactive substances (noradrenaline (NA) and phenylephrine (Phe) for vasoconst...

متن کامل

Factors critical to iontophoretic assessment of vascular reactivity: implications for clinical studies of endothelial dysfunction.

Skin microvascular responses to iontophoresis of acetylcholine, an endothelium-dependent vasodilator, and sodium nitroprusside, an endothelium-independent vasodilator, were measured using a laser Doppler imager whose software controlled iontophoretic current delivery in an integrated fashion. A novel feature involved monitoring voltage across the iontophoresis chambers during current applicatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of vascular research

دوره 46 4  شماره 

صفحات  -

تاریخ انتشار 2009