A comparison between the technical absorbent and ventilated capsule methods for measuring local sweat rate.
نویسندگان
چکیده
This study assessed the accuracy of the technical absorbent (TA) method for measuring local sweat rate (LSR) relative to the well-established ventilated capsule (VC) method during steady-state and nonsteady-state sweating using large and small sample surface areas on the forearm and midback. Forty participants (38 males and two females) cycled at 60% peak oxygen consumption for 75 min in either a temperate [22.3 ± 0.9°C, 32 ± 17% relative humidity (RH)] or warm (32.5 ± 0.8°C, 29 ± 7% RH) environment. Simultaneous bilateral comparisons of 5-min LSR measurements using the TA and VC methods were performed for the back and forearm after 10, 30, 50, and 70 min. LSR values, measured using the TA method, were highly correlated with the VC method at all time points, irrespective of sample surface area and body region (all P < 0.001). On average, ≈ 79% of the variability observed in LSR measured with the VC method was described by the TA method. The mean difference in absolute LSR using the TA method (TA-VC with 95% confidence intervals) was -0.23 [-0.30,-0.16], -0.11 [-0.21,0.00], -0.03 [-0.14,+0.08], and +0.02 [-0.07,+0.11] mg · cm(-2) · min(-1) after 10, 30, 50, and 70 min of exercise, respectively. Duplicate LSR measurements within each method during steady-state sweating were highly correlated (TA: r = 0.96, P < 0.001, n = 20; VC: r = 0.97, P < 0.001, n = 20) with a mean bias of +0.07 ± 0.14 and +0.01 ± 0.10 mg · cm(-2) · min(-1) for TA and VC methods, respectively. The mean smallest detectable difference in LSR was 0.12 and 0.05 mg · min(-1) · cm(-2) for TA and VC methods, respectively. These data support the TA method as a reliable alternative for measuring the rate of sweat appearance on the skin surface.
منابع مشابه
Exploring the mechanisms underpinning sweating: the development of a specialized ventilated capsule for use with intradermal microdialysis
Many studies have aimed to identify the controllers of sweating using ventilated capsules with intradermal microdialysis. It is unclear, however, if the surface area covered by the capsule influences the observed response as a result of differences in the number of sweat glands affected by the infused pharmacological agent relative to the total glands captured by the capsule. We evaluated the a...
متن کاملComparison of sweat rate during graded exercise and the local rate induced by pilocarpine.
Centrally stimulated sweat rate produced by graded exercise until exhaustion was compared to the local sweat rate induced by pilocarpine, often used as a sweating index for healthy individuals. Nine young male volunteers (22 +/- 4 years) were studied in temperate environment in two situations: at rest and during progressive exercise with 25 W increases every 2 min until exhaustion, on a cycle e...
متن کاملThe effect of Therapeutic Touch on Physiological Variables of Mechanically Ventilated Patients in Intensive Care Units
Background: Underlying diseases and aggressive procedures, such as different types of surgery and care, for patients with critical conditions in intensive care units (ICU) may be associated with physiological disorders. Objectives: This study intended to determine the effect of therapeutic touch on physiological variables of patients undergoing mechanical ventilation in ICU. Methods: This...
متن کاملDo nitric oxide synthase and cyclooxygenase contribute to sweating response during passive heating in endurance‐trained athletes?
The aim of our study was to determine if habitual endurance training can influence the relative contribution of nitric oxide synthase (NOS) and cyclooxygenase (COX) in the regulation of sweating during a passive heat stress in young adults. Ten trained athletes and nine untrained counterparts were passively heated until oral temperature (as estimated by sublingual temperature, Tor) increased by...
متن کاملComparison of a local made temporary cement (P-cem), with an imported brand (Temp Bond) using ISO 3107 criteria
Comparison of a local made temporary cement (P-cem), with an imported brand (Temp Bond) using ISO 3107 criteria Dr. Fallahi, M.R.* - Dr. Bayan Zadeh, S.M.** - Dr. Malkomian, L.*** *Dentist. **Assistant Professor of Prosthodontics Dept., Faculty of Dentistry, Tehran University / Medical Sciences. ***Statistician. Abstract Background & Aim: The local made eugenol-free temporary cement (P-cem) has...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of applied physiology
دوره 114 6 شماره
صفحات -
تاریخ انتشار 2013