A New Waveform for Transthoracic Defibrillation

نویسندگان

  • Richard E. Kerber
  • Kirk T. Spencer
چکیده

Background A directionally changing shock electrical vector could facilitate defibrillation by depolarizing myocytes with different orientations vis-A-vis the shock field. Such a changing vector can be achieved by a new waveform for transthoracic defibrillation: overlapping sequential pulses. Our purpose was to evaluate this waveform. Methods and Results Ventricular fibrillation was induced in closed-chest dogs. Single and overlapping truncated exponential waveform pulse shocks were then administered from self-adhesive chest electrodes. Single pulse (control) shocks were 7.5-millisecond duration, while the sequential overlapping pulse shocks, using two different pathways, consisted of two pulses, each 5.0-millisecond duration; the second pulse began 2.5 milliseconds after the start of the first pulse and ended 2.5 milliseconds after the end of the first pulse. Thus, the total duration of the sequential overlapping shock was 7.5 milliseconds. During the overlap phase (2.5 milliseconds), the electrical vector orientation is the summation of the individual vectors. Two different electrode placements and corresponding electrical vector orientations were studied: group 1 (n= 14), left lower chest to right upper chest (pulse 1), overlapped by right lower chest to left upper chest (pulse 2), with the sequence then reversed; and group 2 (n= 11), left chest to right chest (pulse 1) overlapped by dorsal (vertebral column) to ventral (sternum) (pulse 2) with the sequence then reversed. At voltages equivalent to energies of 50, 100, and 150 J, the sequential overlapping pulse shocks achieved higher success rates than the single pulse shocks: At the low energy, 50 J, single pulse shock success rates were 0% (group 2) and 14% (group 1), while the overlapping pulse shocks achieved success rates of 39% (group 2) and 55% (group 1) (P<.05). Similarly, at the highest energy tested, 150 J, single pulse shock success rates were 45% (group 2) and 61% (group 1), while the overlapping pulse shock success was 91% (group 2) and 95% (group 1) (P<.05). In a third group of dogs (n=3), intracardiac plunge electrodes placed orthogonally in the septum showed that the orthogonal components of intracardiac voltage gradient change varied markedly during the three phases of the sequential overlapping shocks, demonstrating the changing direction of the net electrical vector as the shock proceeded. In a fourth group of dogs (n=5), short-duration (2.5-millisecond) single pulse shocks were compared with longer 7.5-millisecond single pulse shocks and with the sequential overlapping pulse shocks, all at equivalent energies. Despite substantially higher current flow, the 2.5-millisecond-duration single pulse shocks were not more effective than 7.5-millisecond single pulse shocks, and both 2.5and 7.5-millisecond duration single pulse shocks had markedly inferior success rates compared with the sequential overlapping pulse shocks. Conclusions Sequential overlapping pulse shock waveforms facilitate defibrillation compared with single pulse shocks of the same total energy. This is due at least in part to the changing orientation of the electrical vector during the multiple pulse shock. (Circulation. 1994;89.2369-2379.)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of a novel rectilinear biphasic waveform with a damped sine wave monophasic waveform for transthoracic ventricular defibrillation. ZOLL Investigators.

OBJECTIVES We compared the efficacy of a novel rectilinear biphasic waveform, consisting of a constant current first phase, with a damped sine wave monophasic waveform during transthoracic defibrillation. BACKGROUND Multiple studies have shown that for endocardial defibrillation, biphasic waveforms have a greater efficacy than monophasic waveforms. More recently, a 130-J truncated exponential...

متن کامل

Multicenter comparison of truncated biphasic shocks and standard damped sine wave monophasic shocks for transthoracic ventricular defibrillation. Transthoracic Investigators.

BACKGROUND The most important factor for improving out-of-hospital ventricular fibrillation survival rates is early defibrillation. This can be achieved if small, lightweight, inexpensive automatic external defibrillators are widely disseminated. Because automatic external defibrillator size and cost are directly affected by defibrillation waveform shape and because of the favorable experience ...

متن کامل

Relative efficacy of monophasic and biphasic waveforms for transthoracic defibrillation after short and long durations of ventricular fibrillation.

BACKGROUND Recently, interest has arisen in using biphasic waveforms for external defibrillation. Little work has been done, however, in measuring transthoracic defibrillation efficacy after long periods of ventricular fibrillation. In protocol 1, we compared the efficacy of a quasi-sinusoidal biphasic waveform (QSBW), a truncated exponential biphasic waveform (TEBW), and a critically damped si...

متن کامل

Is there an Optimal Shape of the Defibrillation Shock: Constant Current vs. Pulsed Biphasic Waveforms?

Three waveforms for transthoracic defibrillation are assessed and compared: the Pulsed Biphasic Waveform (PBW), the Rectilinear Biphasic Waveform (RBW), and the “lossless” constant current (LLCC) pulses. Two indices are introduced: 1) kf = W/W0 – the ratio between the delivered energy W and the energy W0 of a rectangular pulse with the same duration and electric charge; 2) ηC = W/WC0 – the leve...

متن کامل

Comparison of Effectiveness of Relay-Switched, One-Cycle Quasisinusoidal Waveform with Critically Damped Sinusoid Waveform in Transthoracic Defibrillation of 100-Kilogram Calves

Studies o f 240 transthoracic fibrillation-defibrillation episodes in calves of 91-108 kg are reported. The waveform in 120 o f the episodes was a one-cycle, quasisinusoidal waveform having peak currents o f 64 and 3 2 A and half-cycle durations o f 4 and 6 ms. The episodes were interlaced with 120 others involving critically dam ped sinusoid wave­ forms having a 70.2-A peak current at 1.1 m s ...

متن کامل

Transthoracic impedance does not affect defibrillation, resuscitation or survival in patients with out-of-hospital cardiac arrest treated with a non-escalating biphasic waveform defibrillator.

OBJECTIVE This is a study of the influence of transthoracic impedance (TTI) on defibrillation, resuscitation and survival in patients with out-of-hospital cardiac arrest (OHCA), treated with a non-escalating impedance-compensating 150 J biphasic waveform defibrillator. METHODS Cardiac arrest data from two EMS systems were analyzed retrospectively. All witnessed arrests from patients who prese...

متن کامل