Double-Focusing Thermal Triple-Axis Spectrometer at the NCNR

نویسندگان

  • J. W. Lynn
  • Y. Chen
  • S. Chang
  • Y. Zhao
  • S. Chi
  • W. Ratcliff
  • B. G. Ueland
  • R. W. Erwin
چکیده

The new thermal triple-axis spectrometer at the NIST Center for Neutron Research (NCNR) is located at the BT-7 beam port. The 165 mm diameter reactor beam is equipped with a selection of Söller collimators, beam-limiters, and a pyrolytic graphite (PG) filter to tailor the beam for the dual 20×20 cm(2) double-focusing monochromator system that provides monochromatic fluxes exceeding 10(8) n/cm(2)/s onto the sample. The two monochromators installed are PG(002) and Cu(220), which provide incident energies from 5 meV to above 500 meV. The computer controlled analyzer system offers six standard modes of operation, including a diffraction detector, a position-sensitive detector (PSD) in diffraction mode, horizontal energy focusing analyzer with detector, a Q-E mode employing a flat analyzer and PSD, a constant-E mode with the analyzer crystal system and PSD, and a conventional mode with a selection of Söller collimators and detector. Additional configurations for specific measurement needs are also available. This paper discusses the capabilities and performance for this new state-of-the-art neutron spectrometer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

2005 NIST Center for Neutron Research

The Double Crystal Analyzer Linkage (DXAL) is one of 20 being installed in the Multi-Axis Crystal Spectrometer (MACS). Visible are two curved panels holding pyrolytic graphite crystals and collimating blades between them. The design features a single mechanical linkage that allows rotation of each crystal panel by 2θ and each blade by θ while maintaining parallel entering and exiting beam paths...

متن کامل

Abstract Submitted for the MAR11 Meeting of The American Physical Society First Results from the Triple-axis Spectrometer at OPAL

Submitted for the MAR11 Meeting of The American Physical Society First Results from the Triple-axis Spectrometer at OPAL SERGEY DANILKIN, MOHANA YETHIRAJ, THOMAS SAERBECK, FRANK KLOSE, Australian Nuclear Science and Technology Organization — The thermal triple-axis spectrometer TAIPAN is the first instrument for inelastic scattering at Australian research reactor OPAL. TAIPAN started operation ...

متن کامل

The Magnetic Correlations and Fluctuations in the Geometrically Frustrated Antiferromagnetic Spinel CdCr2O4: An Experiment Using the SPINS Triple-Axis Spectrometer Summer School on Methods and Applications of Neutron Spectroscopy NIST Center for Neutron Research

We will study the magnetic correlations in the geometrically frustrated antiferromagnetic spinel CdCr2O4 using inelastic neutron scattering. In so doing, we will gain an an understanding of the principles of Triple-Axis Spectroscopy (TAS) and learn how to analyze the TAS data obtained to extract physical information about the system being studied.

متن کامل

Concepts and Engineering Aspects of a Neutron Resonance Spin-Echo Spectrometer for the National Institute of Standards and Technology Center for Neutron Research

Following a brief introduction, the Neutron Resonance Spin-Echo (NRSE) principle is discussed classically in Sec. 2. In Sec. 3, two idealized 4-coil NRSE spectrometers are discussed (one using single π-flipper coil units and one using paired "bootstrap" coils); some idealized (exact π-flip) expressions are given for the spin-echo signal and some theoretical limitations are discussed. A more qua...

متن کامل

Adapting a triple-axis spectrometer for small angle neutron scattering measurements.

Small angle neutron scattering (SANS) instruments typically cover a q (scattering vector) range from 0.001 to 0.6 A(-1). This range in q is achieved through a combination of cold neutrons (lambda>4 A) and a highly collimated beam. However, as a direct result of the unavailability of a cold source at the Canadian Neutron Beam Centre (CNBC), we have resorted to adapting a triple-axis spectrometer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 117  شماره 

صفحات  -

تاریخ انتشار 2012