Cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary heart disease (CE-MARC): a prospective trial

نویسندگان

  • John P Greenwood
  • Neil Maredia
  • John F Younger
  • Julia M Brown
  • Jane Nixon
  • Colin C Everett
  • Petra Bijsterveld
  • John P Ridgway
  • Aleksandra Radjenovic
  • Catherine J Dickinson
  • Stephen G Ball
  • Sven Plein
چکیده

BACKGROUND In patients with suspected coronary heart disease, single-photon emission computed tomography (SPECT) is the most widely used test for the assessment of myocardial ischaemia, but its diagnostic accuracy is reported to be variable and it exposes patients to ionising radiation. The aim of this study was to establish the diagnostic accuracy of a multiparametric cardiovascular magnetic resonance (CMR) protocol with x-ray coronary angiography as the reference standard, and to compare CMR with SPECT, in patients with suspected coronary heart disease. METHODS In this prospective trial patients with suspected angina pectoris and at least one cardiovascular risk factor were scheduled for CMR, SPECT, and invasive x-ray coronary angiography. CMR consisted of rest and adenosine stress perfusion, cine imaging, late gadolinium enhancement, and MR coronary angiography. Gated adenosine stress and rest SPECT used (99m)Tc tetrofosmin. The primary outcome was diagnostic accuracy of CMR. This trial is registered at controlled-trials.com, number ISRCTN77246133. FINDINGS In the 752 recruited patients, 39% had significant CHD as identified by x-ray angiography. For multiparametric CMR the sensitivity was 86·5% (95% CI 81·8-90·1), specificity 83·4% (79·5-86·7), positive predictive value 77·2%, (72·1-81·6) and negative predictive value 90·5% (87·1-93·0). The sensitivity of SPECT was 66·5% (95% CI 60·4-72·1), specificity 82·6% (78·5-86·1), positive predictive value 71·4% (65·3-76·9), and negative predictive value 79·1% (74·8-82·8). The sensitivity and negative predictive value of CMR and SPECT differed significantly (p<0·0001 for both) but specificity and positive predictive value did not (p=0·916 and p=0·061, respectively). INTERPRETATION CE-MARC is the largest, prospective, real world evaluation of CMR and has established CMR's high diagnostic accuracy in coronary heart disease and CMR's superiority over SPECT. It should be adopted more widely than at present for the investigation of coronary heart disease. FUNDING British Heart Foundation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prognostic value of CMR and SPECT in suspected coronary heart disease: long term follow-up of the CE-MARC study

Background CE-MARC established the comparative diagnostic performance of cardiovascular magnetic resonance (CMR) and single photon emission computed tomography (SPECT) in patients with suspected coronary heart disease. However, there are no prospective, prognostic data comparing the two modalities in the same patient population. Our objective was to establish the comparative ability of CMR and ...

متن کامل

Rationale and design of the Clinical Evaluation of Magnetic Resonance Imaging in Coronary heart disease 2 trial (CE-MARC 2): A prospective, multicenter, randomized trial of diagnostic strategies in suspected coronary heart disease

BACKGROUND A number of investigative strategies exist for the diagnosis of coronary heart disease (CHD). Despite the widespread availability of noninvasive imaging, invasive angiography is commonly used early in the diagnostic pathway. Consequently, approximately 60% of angiograms reveal no evidence of obstructive coronary disease. Reducing unnecessary angiography has potential financial saving...

متن کامل

Comparative use of exercise tolerance testing, SPECT and CMR, alone and in combination, for the diagnosis of coronary heart disease in the CE-MARC study

Background Whilst exercise tolerance testing (ETT) has been a corner stone investigation for the diagnosis of patients with suspected angina, increasingly imaging techniques have gained prominence. We aimed to determine the diagnostic accuracy of ETT in the CE-MARC study population compared to single photon emission computed tomography (SPECT) and cardiovascular magnetic resonance (CMR) and to ...

متن کامل

Diagnostic accuracy of the core components of a multi-parametric cardiovascular magnetic resonance imaging protocol: a CE-MARC sub-study

Background The CE-MARC study was the largest prospective evaluation of the diagnostic accuracy of cardiovascular magnetic resonance (CMR) in coronary artery disease (CAD), demonstrating its superiority over single-photon emission computed tomography [1]. The trial adopted a multi-parametric protocol assessing ventricular function, myocardial perfusion, viability (with late gadolinium enhancemen...

متن کامل

Comparison of cardiovascular magnetic resonance and single-photon emission computed tomography in women with suspected coronary artery disease from the Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease (CE-MARC) Trial.

BACKGROUND Coronary artery disease is the leading cause of death in women, and underdiagnosis contributes to the high mortality. This study compared the sex-specific diagnostic performance of cardiovascular magnetic resonance (CMR) and single-photon emission computed tomography (SPECT). METHODS AND RESULTS A total of 235 women and 393 men with suspected angina underwent CMR, SPECT, and x-ray ...

متن کامل

Cardiovascular magnetic resonance stress perfusion compared to single-photon emission computed tomography (SPECT) in patients with left main stem disease: a CE-MARC substudy

We compared detection rates for cardiovascular magnetic resonance (CMR) perfusion and single photon emission tomography (SPECT) in the subset of patients from the CE-MARC study with significant left main stem (LMS) disease. Detection rates for LMS disease by CMR perfusion were higher than for SPECT, and CMR identified a classical LMS pattern with higher frequency. Visual perfusion defects occur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 379  شماره 

صفحات  -

تاریخ انتشار 2012