Quantitative RT-PCR: limits and accuracy.

نویسندگان

  • F Souazé
  • A Ntodou-Thomé
  • C Y Tran
  • W Rostène
  • P Forgez
چکیده

In this paper we determine the limits and accuracy of quantitative reverse transcription (RT)-PCR using a modification of the original protocol. The quantification of mRNA with this procedure requires a preliminary estimation of the target molecule (TM) concentration, established from experiments with an internal control molecule (ICM). A definitive quantification is then attained from serial dilutions of the reverse transcription reaction. The success of this latter step is dependent on maintaining an equivalent number of TM and ICM in the reaction. The purpose of our study was to evaluate the influence of the deviation between the TM and the ICM on the result. We show here that we can control the accuracy of the assay by fixing the limit of the TM/ICM ratio. Indeed, when the TM/ICM ratio is between 0.66 and 1.5 (i.e., the difference between TM and ICM is 1.5-fold), the final result has an error of approximately 10%. Exceeding this limit produces errors approaching 60%, as in the case of TM/ICM = 2. When the above conditions are respected, a difference as small as 20% between two samples can be determined with an accuracy of 95%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nanoliter high throughput quantitative PCR

Understanding biological complexity arising from patterns of gene expression requires accurate and precise measurement of RNA levels across large numbers of genes simultaneously. Real time PCR (RT-PCR) in a microtiter plate is the preferred method for quantitative transcriptional analysis but scaling RT-PCR to higher throughputs in this fluidic format is intrinsically limited by cost and logist...

متن کامل

Development and Validation of an Externally Standardised Quantitative Insulin-like Growth Factor-1 RT-PCR Using LightCycler

RT-PCR has a detection limit 10–100 fold lower than protection-assay or northern hybridisation, respectively. The RT-ribonuclease PCR quantification technique of choice depends on the target sequence, the expected range of the mRNA amount present in the tissue, the degree of accuracy required, and whether quantification needs to be relative or absolute. Externally standardised RT-PCR with quant...

متن کامل

Reliable gene expression analysis by reverse transcription-quantitative PCR: reporting and minimizing the uncertainty in data accuracy.

Reverse transcription-quantitative PCR (RT-qPCR) has been widely adopted to measure differences in mRNA levels; however, biological and technical variation strongly affects the accuracy of the reported differences. RT-qPCR specialists have warned that, unless researchers minimize this variability, they may report inaccurate differences and draw incorrect biological conclusions. The Minimum Info...

متن کامل

Comparing the Diagnostic Power of Chest CT Scan and RT-PCR in Diagnosis of COVID-19

Background and purpose: Proper diagnosis of patients with COVID-19 is one of the challenges in medical centers. RT-PCR is the standard and reference test in diagnosis of patients with COVID-19. This study aimed at accelerating the correct diagnosis of COVID-19 and the diagnostic power of chest CT scan and RT-PCR. Materials and methods: This study was performed in 569 patients with COVID-19 adm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioTechniques

دوره 21 2  شماره 

صفحات  -

تاریخ انتشار 1996