A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

نویسندگان

  • A. Vakily
  • H. Parsaei
  • M.M. Movahhedi
  • M.A. Sahmeddini
چکیده

BACKGROUND Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Several methods have been developed for this purpose, but a majority of them are either invasive, too expensive or need special expertise and experience. Besides, they are not usually risk free and have consequences. OBJECTIVE Here, a semi-invasive system was designed and developed for continuous CO measurement via analyzing and processing arterial pulse waves. RESULTS Quantitative evaluation of developed CO estimation system was performed using 7 signals. It showed that it has an acceptable average error of (6.5%) in estimating CO. In addition, this system has the ability to consistently estimate this parameter and to provide a CO versus time curve that assists in tracking changes of CO. Moreover, the system provides such curve for systolic blood pressure, diastolic blood pressure, average blood pressure, heart rate and stroke volume. CONCLUSION Evaluation of the results showed that the developed system is capable of accurately estimating CO. The curves which the system provides for important parameters may be valuable in monitoring hemodynamic status of high-risk surgical patients and critically ill patients in Intensive Care Units (ICU). Therefore, it could be a suitable system for monitoring hemodynamic status of critically ill patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Arterial waveform analysis.

The bedside measurement of continuous arterial pressure values from waveform analysis has been routinely available via indwelling arterial catheterization for >50 years. Invasive blood pressure monitoring has been utilized in critically ill patients, in both the operating room and critical care units, to facilitate rapid diagnoses of cardiovascular insufficiency and monitor response to treatmen...

متن کامل

TRANSLATIONAL PHYSIOLOGY Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis

Lu, Zhenwei, and Ramakrishna Mukkamala. Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis. J Appl Physiol 101: 598–608, 2006; doi:10.1152/japplphysiol.01488.2005.—We present an evaluation of a novel technique for continuous (i.e., automatic) monitoring of relative cardiac output (CO) changes by long time interval analysis of a...

متن کامل

Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis.

We present an evaluation of a novel technique for continuous (i.e., automatic) monitoring of relative cardiac output (CO) changes by long time interval analysis of a peripheral arterial blood pressure (ABP) waveform in humans. We specifically tested the mathematical analysis technique based on existing invasive and noninvasive hemodynamic data sets. With the former data set, we compared the app...

متن کامل

Innovative Methodology Continuous cardiac output and left atrial pressure monitoring by long time interval analysis of the pulmonary artery pressure waveform: proof of concept in dogs

Xu D, Olivier NB, Mukkamala R. Continuous cardiac output and left atrial pressure monitoring by long time interval analysis of the pulmonary artery pressure waveform: proof of concept in dogs. J Appl Physiol 106: 651–661, 2009. First published December 4, 2008; doi:10.1152/japplphysiol.90834.2008.—We developed a technique to continuously (i.e., automatically) monitor cardiac output (CO) and lef...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017