Photothermal cantilever actuation for fast single-molecule force spectroscopy.
نویسندگان
چکیده
Photothermal cantilever excitation provides a fast and easy to implement means to control the deflection of standard atomic force microscopy cantilevers. Minute heat pulses yield deflections on the order of several tens of nanometers or when the deflection is kept constant, forces of several hundreds of piconewton can be applied. In our case these pulses resulted in less than 1 K temperature changes at the sample position. Here we present and characterize the implementation of photothermal actuation for single-molecule force-spectroscopy experiments. When molecules are stretched under force-clamp conditions, fast control cycles that re-establish the pulling force after the rupture of molecular domains are essential for detecting the complete unfolding pattern with high precision. By combining the fast response of photothermal cantilever excitation with a conventional piezoactuator, a fast force-clamp with high accuracy and large working distances is reached. Simple feedback mechanisms and standard cantilever geometries lead to step response times of less than 90 micros, which is more than one order of magnitude faster than those of conventional force-clamp systems that are based only on piezo feedback. We demonstrate the fast and accurate performance of the setup by unfolding a protein construct consisting of one green fluorescent protein and eight surrounding immunoglobulin domains at constant force.
منابع مشابه
Tip-sample distance control using photothermal actuation of a small cantilever for high-speed atomic force microscopy.
We have applied photothermal bending of a cantilever induced by an intensity-modulated infrared laser to control the tip-surface distance in atomic force microscopy. The slow response of the photothermal expansion effect is eliminated by inverse transfer function compensation. By regulating the laser power and regulating the cantilever deflection, the tip-sample distance is controlled; this ena...
متن کاملRevisiting atomic force microscopy force spectroscopy sensitivity for single molecule studies
Recently, the rapid advances in quantitative biology and polymer science have led to the atomic force microscope AFM being extensively employed for single-molecule force spectroscopy. Deflection sensitivity, a critical factor in single molecule force spectroscopy, is changed due to the change in bending shape of AFM cantilever when a single molecule is attached to the AFM cantilever tip. We qua...
متن کاملPhotothermal excitation for improved cantilever drive performance in tapping mode atomic force microscopy
Photothermal excitation is an alternative cantilever drive mechanism for tapping mode atomic force microscopy. It uses a power-modulated laser focused on the cantilever to directly drive its oscillation, producing cantilever tunes that match the thermal response almost perfectly. This enables quantitatively accurate AFM imaging and viscoelastic nanomechanical mapping in all environments. In add...
متن کاملMinimizing pulling geometry errors in atomic force microscope single molecule force spectroscopy.
In atomic force microscopy-based single molecule force spectroscopy (AFM-SMFS), it is assumed that the pulling angle is negligible and that the force applied to the molecule is equivalent to the force measured by the instrument. Recent studies, however, have indicated that the pulling geometry errors can drastically alter the measured force-extension relationship of molecules. Here we describe ...
متن کاملOptimizing 1-μs-Resolution Single-Molecule Force Spectroscopy on a Commercial Atomic Force Microscope
Atomic force microscopy (AFM)-based single-molecule force spectroscopy (SMFS) is widely used to mechanically measure the folding and unfolding of proteins. However, the temporal resolution of a standard commercial cantilever is 50-1000 μs, masking rapid transitions and short-lived intermediates. Recently, SMFS with 0.7-μs temporal resolution was achieved using an ultrashort (L = 9 μm) cantileve...