Clavicle Fracture after Coracoclavicular Ligament Reconstruction: A Biomechanical and Finite Element Evaluation of Clavicle Fracture Risk

نویسندگان

  • Peter Gustafson
  • Andrew Geeslin
  • Mark Omwansa
  • Mark J. Sytsma
چکیده

This open‐access article is published and distributed under the Creative Commons Attribution ‐ NonCommercial ‐ No Derivatives License (http://creativecommons.org/licenses/by‐nc‐nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For reprints and permission queries, please visit SAGE’s Web site at http://www.sagepub.com/journalsPermissions.nav. Clavicle Fracture after Coracoclavicular Ligament Reconstruction: A Biomechanical and Finite Element Evaluation of Clavicle Fracture Risk

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coracoid Process Avulsion Fracture at the Coracoclavicular Ligament Attachment Site in an Osteoporotic Patient with Acromioclavicular Joint Dislocation

Coracoid fractures are uncommon, mostly occur at the base or neck of the coracoid process (CP), and typically present with ipsilateral acromioclavicular joint (ACJ) dislocation. However, CP avulsion fractures at the coracoclavicular ligament (CCL) attachment with ACJ dislocation have not been previously reported. A 59-year-old woman receiving glucocorticoid treatment fell from bed and complaine...

متن کامل

Arthroscopically Assisted Fixation of Unstable Distal Third Clavicle Fractures

INTRODUCTION Clavicle fractures are common injuries, representing 35 to 45% of fractures of the shoulder girdle. Fifteen to 25% of those involve the distal portion of the clavicle. Previously, non-operative management of midshaft clavicle fractures was based on the premise that even grossly malunited fractures had a minimal impact on functional outcomes. However, level I evidence supports the i...

متن کامل

Titanium Elastic Nail (TEN) versus Reconstruction Plate Repair of Midshaft Clavicular Fractures: A Finite Element Study

BACKGROUND The biomechanical characteristics of midshaft clavicular fractures treated with titanium elastic nail (TEN) is unclear. This study aimed to present a biomechanical finite element analysis of biomechanical characteristics involved in TEN fixation and reconstruction plate fixation for midshaft clavicular fractures. METHODS Finite element models of the intact clavicle and of midshaft ...

متن کامل

Acromioclavicular Joint Dislocation with Ipsilateral Mid Third Clavicle, Mid Shaft Humerus and Coracoid Process Fracture – A Case Report

INTRODUCTION The clavicle, humerus and acromioclavicular (AC) joint separately are very commonly involved in traumatic injuries around the shoulder. Acromioclavicular joint dislocation with distal clavicle fracture is a well recognized entity in clinical practice. AC joint dislocation with mid shaft clavicle fracture is uncommon and only few cases have been reported in literature. However, to t...

متن کامل

Unplanned Operations and Adverse Events after Surgery for Diaphyseal Fracture of the Clavicle

Background: We used a database of patients treated at three hospitals to study the primary null hypothesis that thereare no factors associated with unplanned reoperations or adverse events after surgical repair for diaphyseal claviclefracture. Additionally we addressed the following secondary study questions: 1. What is the prevalence of unplannedreoperations or adverse events...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017