Modeling versus Accuracy in EEG and MEG Data
نویسندگان
چکیده
منابع مشابه
The advantage of combining MEG and EEG: comparison to fMRI in focally stimulated visual cortex.
To exploit the high (millisecond) temporal resolution of magnetoencephalography (MEG) and electroencephalography (EEG) for measuring neuronal dynamics within well-defined brain regions, it is important to quantitatively assess their localizing ability. Previous modeling studies and empirical data suggest that a combination of MEG and EEG signals should yield the most accurate localization, due ...
متن کاملDivergent Cortical Generators of MEG and EEG during Human Sleep Spindles Suggested by Distributed Source Modeling
BACKGROUND Sleep spindles are approximately 1-second bursts of 10-15 Hz activity, occurring during normal stage 2 sleep. In animals, sleep spindles can be synchronous across multiple cortical and thalamic locations, suggesting a distributed stable phase-locked generating system. The high synchrony of spindles across scalp EEG sites suggests that this may also be true in humans. However, prior M...
متن کاملA study of dipole localization accuracy for MEG and EEG using a human skull phantom.
OBJECTIVE To investigate the accuracy of forward and inverse techniques for EEG and MEG dipole localization. DESIGN AND METHODS A human skull phantom was constructed with brain, skull and scalp layers and realistic relative conductivities. Thirty two independent current dipoles were distributed within the 'brain' region and EEG and MEG data collected separately for each dipole. The true dipol...
متن کاملA Parametric Empirical Bayesian framework for fMRI-constrained MEG/EEG source reconstruction
We describe an asymmetric approach to fMRI and MEG/EEG fusion in which fMRI data are treated as empirical priors on electromagnetic sources, such that their influence depends on the MEG/EEG data, by virtue of maximizing the model evidence. This is important if the causes of the MEG/EEG signals differ from those of the fMRI signal. Furthermore, each suprathreshold fMRI cluster is treated as a se...
متن کاملMonte Carlo simulation studies of EEG and MEG localization accuracy.
Both electroencephalography (EEG) and magnetoencephalography (MEG) are currently used to localize brain activity. The accuracy of source localization depends on numerous factors, including the specific inverse approach and source model, fundamental differences in EEG and MEG data, and the accuracy of the volume conductor model of the head (i.e., the forward model). Using Monte Carlo simulations...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1998