BACKGROUND Whether outcomes differ between sexes following treatment with pacemakers (PM), implantable cardioverter defibrillators, and cardiac resynchronization therapy (CRT) devices is unclear. METHODS AND RESULTS Consecutive US patients with newly implanted PM, implantable cardioverter defibrillators, and CRT devices from a large remote monitoring database between 2008 and 2011 were included in this observational cohort study. Sex-specific all-cause survival postimplant was compared within each device type using a multivariable Cox proportional hazards model, stratified on age and adjusted for remote monitoring utilization and ZIP-based socioeconomic variables. A total of 269 471 patients were assessed over a median 2.9 [interquartile range, 2.2, 3.6] years. Unadjusted mortality rates (MR; deaths/100 000 patient-years) were similar between women versus men receiving PMs (n=115 076, 55% male; MR 4193 versus MR 4256, respectively; adjusted hazard ratio, 0.87; 95% CI, 0.84-0.90; P<0.001) and implantable cardioverter defibrillators (n=85 014, 74% male; MR 4417 versus MR 4479, respectively; adjusted hazard ratio, 0.98; 95% CI, 0.93-1.02; P=0.244). In contrast, survival was superior in women receiving CRT defibrillators (n=61 475, 72% male; MR 5270 versus male MR 7175; adjusted hazard ratio, 0.73; 95% CI, 0.70-0.76; P<0.001) and also CRT pacemakers (n=7906, 57% male; MR 5383 versus male MR 7625, adjusted hazard ratio, 0.69; 95% CI, 0.61-0.78; P<0.001). This relative difference increased with time. These results were unaffected by age or remote monitoring utilization. CONCLUSIONS Women accounted for less than 30% of high-voltage implants and fewer than half of low-voltage implants in a large, nation-wide cohort. Survival for women and men receiving implantable cardioverter defibrillators and PMs was similar, but dramatically greater for women receiving both defibrillator- and PM-based CRT.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erosive Pressure Dermatitis Associated with Cardiac Pacemaker

Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...

متن کامل

Sex differences in implantable cardioverter-defibrillator implantation indications and outcomes: lessons from the Nationwide Israeli-ICD Registry.

AIMS Implantable cardioverter-defibrillators (ICDs) improve survival in certain high arrhythmic risk populations. However, there are sex differences regarding both the utilization and the benefit of these devices. Using a prospective national ICD registry, we aim to compare the indications for ICD implantation as well as outcomes in implanted women vs. men. METHODS AND RESULTS All subjects im...

متن کامل

Remote Monitoring and Outcomes in Pacemaker and Defibrillator Patients: Big Data Saving Lives?

R emote monitoring (RM) of cardiac implantable devices now enables daily monitoring and notification of device function and patient clinical status. Past guideline recommendations have endorsed in-person follow-up of device patients or RM every 3 to 6 months (1–3), but RM offers a simpler alternative, which surveys have shown patients prefer and physicians find straightforward to use (4,5). Lar...

متن کامل

Implantable Cardiac Devices

Electrical cardiac pacing for the management of bradyarrhythmias was first described in 1952, and permanent transvenous pacing devices were introduced into clinical practice in the early 1960s. The first devices for endocardial defibrillation were implanted in surviving victims of sudden cardiac death in 1980. Implanted electrical devices for the management of cardiac dysrhythmias have changed ...

متن کامل

Primary Prevention Implantable Cardioverter Defibrillator (ICD) Therapy in Women-Data From a Multicenter French Registry.

BACKGROUND There are limited data describing sex specificities regarding implantable cardioverter defibrillators (ICDs) in the real-world European setting. METHODS AND RESULTS Using a large multicenter cohort of consecutive patients referred for ICD implantation for primary prevention (2002-2012), in ischemic and nonischemic cardiomyopathy, we examined the sex differences in subjects' charact...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017