Inverse treatment planning for spinal robotic radiosurgery: an international multi‐institutional benchmark trial

نویسندگان

  • Oliver Blanck
  • Lei Wang
  • Wolfgang Baus
  • Jimm Grimm
  • Thomas Lacornerie
  • Joakim Nilsson
  • Sergii Luchkovskyi
  • Isabel Palazon Cano
  • Zhenyu Shou
  • Myriam Ayadi
  • Harald Treuer
  • Romain Viard
  • Frank‐Andre Siebert
  • Mark K.H. Chan
  • Guido Hildebrandt
  • Jürgen Dunst
  • Detlef Imhoff
  • Stefan Wurster
  • Robert Wolff
  • Pantaleo Romanelli
  • Eric Lartigau
  • Robert Semrau
  • Scott G. Soltys
  • Achim Schweikard
چکیده

Stereotactic radiosurgery (SRS) is the accurate, conformal delivery of high-dose radiation to well-defined targets while minimizing normal structure doses via steep dose gradients. While inverse treatment planning (ITP) with computerized optimization algorithms are routine, many aspects of the planning process remain user-dependent. We performed an international, multi-institutional benchmark trial to study planning variability and to analyze preferable ITP practice for spinal robotic radiosurgery. 10 SRS treatment plans were generated for a complex-shaped spinal metastasis with 21 Gy in 3 fractions and tight constraints for spinal cord (V14Gy < 2 cc, V18Gy < 0.1 cc) and target (coverage > 95%). The resulting plans were rated on a scale from 1 to 4 (excellent-poor) in five categories (constraint compliance, optimization goals, low-dose regions, ITP complexity, and clinical acceptability) by a blinded review panel. Additionally, the plans were mathemati-cally rated based on plan indices (critical structure and target doses, conformity, monitor units, normal tissue complication probability, and treatment time) and compared to the human rankings. The treatment plans and the reviewers' rankings varied substantially among the participating centers. The average mean overall rank was 2.4 (1.2-4.0) and 8/10 plans were rated excellent in at least one category by at least one reviewer. The mathematical rankings agreed with the mean overall human rankings in 9/10 cases pointing toward the possibility for sole mathematical plan quality comparison. The final rankings revealed that a plan with a well-balanced trade-off among all planning objectives was preferred for treatment by most par-ticipants, reviewers, and the mathematical ranking system. Furthermore, this plan was generated with simple planning techniques. Our multi-institutional planning study found wide variability in ITP approaches for spinal robotic radiosurgery. The participants', reviewers', and mathematical match on preferable treatment plans and ITP techniques indicate that agreement on treatment planning and plan quality can be reached for spinal robotic radiosurgery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variability in spine radiosurgery treatment planning – results of an international multi-institutional study

BACKGROUND The aim of this study was to quantify the variability in spinal radiosurgery (SRS) planning practices between five international institutions, all member of the Elekta Spine Radiosurgery Research Consortium. METHODS Four institutions provided one representative patient case each consisting of the medical history, CT and MR imaging. A step-wise planning approach was used where, afte...

متن کامل

Fiducial-free real-time image-guided robotic radiosurgery for tumors of the sacrum/pelvis.

BACKGROUND AND PURPOSE Radiosurgery is a non-invasive treatment for many spinal tumors. Sacral radiosurgery, however, requires invasive fiducial marker insertion to target and track the tumor's position. We present preliminary clinical results and phantom accuracy measurements of sacral radiosurgery using fiducial-free alignment based on vertebral anatomy distant to tumor location. MATERIALS ...

متن کامل

Robotic radiosurgery with noncylindrical collimators.

In radiosurgery, a moving beam of radiation acts as an ablative surgical instrument. Conventional systems for radiosurgery use a cylindrical radiation beam of fixed cross section. The radiation source can be moved only along simple, standardized paths. A new radiosurgical system based on a six-degree-of-freedom robotic arm has been developed to overcome limitations of conventional systems. We a...

متن کامل

A multi-national report on methods for institutional credentialing for spine radiosurgery

BACKGROUND Stereotactic body radiotherapy and radiosurgery are rapidly emerging treatment options for both malignant and benign spine tumors. Proper institutional credentialing by physicians and medical physicists as well as other personnel is important for the safe and effective adoption of spine radiosurgery. This article describes the methods for institutional credentialing for spine radiosu...

متن کامل

Clinical implementation of an automated planning system for gamma knife radiosurgery.

PURPOSE To evaluate an automated treatment planning system for gamma knife radiosurgery. This planning system was developed in our clinic and is now in routine clinical use. The system simultaneously optimizes the shot sizes, locations, and weights. It also guides the user in selecting the total number of radiation shots. METHODS AND MATERIALS We assessed the clinical significance of the auto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016