Comparison of the location and extent of BOLD activation in high spatial resolution SE and GE fMRI of the Motor Cortex at 7T
نویسندگان
چکیده
Introduction: fMRI studies generally employ gradient-echo (GE) BOLD contrast due to the limited signal change and signal-to-noise ratio (SNR) of spin echo (SE) BOLD contrast at standard field strength. Ultra-high field (7T) provides increased BOLD contrast-to-noise ratio (CNR) and decreases the contribution that large vessels make to GE BOLD contrast, due to higher capillary contribution and the suppression of intravascular BOLD signal as a result of shortened blood T2 [1]. However, the extravascular venous signal will still contribute to GE BOLD maps at 7T. In SE BOLD contrast, extravascular static dephasing effects around large vessels are refocused causing the SE signal to arise mainly due to microvascular effects [2, 3]. A limited number of studies have compared GE and SE BOLD contrast, and these have generally been restricted to the visual cortex (due to its large response) with data being acquired at relatively coarse spatial resolution [4]. Here, the increased BOLD CNR at 7T is exploited to assess GEand SE-BOLD responses to a simple motor task at high (1.5 mm isotropic) spatial resolution. We investigate CNR, fractional signal change as a function of echo time, spatial specificity of SE BOLD and the localisation of GE and SE activation in relation to underlying venous blood vessels. Methods: Six subjects participated in the study. Scanning was performed on a 7T Philips Achieva System with a 16-channel array coil. Protocol: 1.5 mm isotropic resolution, axial, multi-slice, single shot spin echo EPI data were acquired using SENSE 2 with a field of view (FOV) of 192 x 72 mm (AP x RL) and image based shimming. Volumes comprising 16 contiguous axial slices spanning the right primary motor cortex were acquired in a TR of 2.4 s. An outer-volume suppression slab was used to prevent signal fold-over in the phase encode (RL) direction and Slice Selective Gradient Reversal (SSGR) [5] used to suppress the fat signal. In addition, a high-resolution, T2-weighted image (0.25x0.25x1.5 mm) was acquired to identify large veins. Paradigm: A block motor paradigm was performed. This consisted of a 16.8 s rest period followed by 14.4 s of finger tapping with the left hand, repeated for 6 cycles. The motor task was repeated for SE echo times of 30, 35, 40, 45, 50 and 55 ms, and for a single GE-BOLD scan at TE 25 ms. Following functional scans, GEand SE-EPI measurements were acquired at a range of echo times to form T2 and T2* maps. Analysis: Data were realigned using AFNI (http://afni.nimh.nih.gov/afni) and analyzed using a general linear model in FEAT (FSL, Oxford, UK). Z-statistic maps were obtained for each echo time. An average Z-map based on SE data from all TE’s was formed. Threshold-free cluster enhancement (TFCE) [6] was then applied to the Z-score statistical maps. TFCE maps were threshold at the 95 percentile to form a SE-ROI and a GE-ROI. The cluster size and T2 distribution were determined for each ROI, and the CNR, number of active voxels, and the fractional signal change (ΔS/S) at each echo time also measured. ΔR2 was estimated assuming a linear relation between (ΔS/S) and TE. Venous vessel masks were generated for four subjects by thresholding the phase data from the high resolution T2-weighted image. Masks were registered to the functional data and used to determine the fraction of active voxels common to veins. Results: Significant activation was found for all subjects across all echo times. Figure 1 shows the average SE-ROI and GE-ROI for a representative subject. The T2 map shows a clear band of low T2 values (~ 25 ms) along the motor cortex. The number of active voxels for this subject was largest for TE = 30 ms. Figure 2 shows the percentage signal change in the SE-ROI (mean across cycles) for SE data at each echo time and for the GE data. Figure 3 shows the SE percentage signal change as a function of TE for both the SE-ROI (blue) and GE-ROI (red). Assuming a linear relation, the mean ΔR2 for the SE-ROI was -1.59 ± 0.05 s and -0.74 ± 0.06 s for the GE-ROI. The CNR for GE data was 20.1±2.4 (mean ± stderr) compared to 7.8±1.9 for SE (TE=45ms) in the SE-ROI. Figure 4 shows an example of the phase data used to create the venous masks. Results in Table 1 show that 22% more voxels overlap the venous mask for the GE versus SE ROI when the whole ROI is considered, and 52% more when analysing the voxels which did not overlap in SE and GE ROIs. Discussion: The mode and median of the T2 distribution (averaged across subjects) in the SE-ROI were 34 ± 5 ms and 43 ± 7 ms. The low T2 values reflect the dark band seen in the motor strip on the T2 map, and agrees with low signal in this area reported by others [7]. ΔR2 changes were similar to previous studies for the GE-ROI [8], but greater for the SE-ROI. This difference is likely due to reduced partial volume effects at high resolution and is also influenced by the size of the ROI. A higher proportion of GE activation was found to occur in voxels classified to have a high venous contribution than for SE. Robust BOLD responses can be detected with SE fMRI at high resolution at 7T. References: [1] Thulborn et al., Biochem. Biophys. Acat. 714, 1982. [2] Boxerman et al., MRM., 34, 1995. [3] Yacoub et al., MRM, 49, 2003. [4] Duong et al., MRM., 49, 2003. [5] Park et al., MRM, 4, 2005 [6] Smith et al., Neuroimage, 44, 2009. [7] Haacke, MRI, 23, 2005. [8] Schafer et al., Magn. Reson. Mater. Phy., 21, 2008. Figure 1: Top: GE-ROI overlaid on GE EPI image, Middle: SE-ROI overlaid on SE EPI image (TE=45ms). SE-ROI contains 777 voxels and GE-ROI 843 voxels, with 365 common. Bottom: T2 map illustrating low T2 band along the motor cortex.
منابع مشابه
An fMRI study of human visual cortex in response to spatiotemporal properties of visual stimuli
ABSTRACT Background: The brain response to temporal frequencies (TF) has been already reported, but with no study reported for different TF with respect to various spatial frequencies (SF). Materials and Methods: fMRI was performed by 1.5T GE-system in 14 volunteers during checkerboard, with TFs of 4, 6, 8 and 10Hz in low and high SFs of 0.5 and 8cpd. Results: Average percentage BOLD signa...
متن کاملEvaluation of Sensory Pathways in Spinal Cord by Comparison of fMRI Methodologies
Introduction: Today, clinicians and neuroscientists need to have a comprehensive survey of neurological pathologies and injuries. For the First-time, SEEP contrast and Spin-Echo pulse sequences was used for functional imaging of the Lumbar spinal cord. This method used by several research groups for Spinal cord mapping, but other researchers tried to improve BOLD fMRI to Spina...
متن کاملSpatial specificity of CBV and BOLD fMRI in monkey striate cortex at 4.7T and 7T
Introduction High resolution fMRI allows us to determine more accurately the origins of the fMRI signal. This has shown that even at high field, the GE-BOLD signal has still a large vascular contribution [1]. Alternative methods like SEand monocrystalline iron oxide nanocolloid (MION)-based methods have been shown to be spatially more specific than conventional BOLD, and are able to reveal func...
متن کاملRepeatability of Detecting Visual Cortex Activity in Functional Magnetic Resonance Imaging
Introduction As functional magnetic resonance imaging (fMRI) is too expensive and time consuming, its frequent implementation is difficult. The aim of this study is to evaluate repeatability of detecting visual cortex activity in fMRI. Materials and Methods In this study, 15 normal volunteers (10 female, 5 male; Mean age±SD: 24.7±3.8 years) attended. Functional magnetic resonance images were ob...
متن کاملDistinguishing pial and laminar gradient-echo BOLD signals at 7 Tesla
Introduction With high field scanners and multi-channel coil arrays becoming more readily available, high resolution fMRI methods may be capable of detecting neural responses at the laminar level. First results in animals indicate that gradient-echo (GE) is not able to depict laminar activation [1-4] and this has been attributed to the large BOLD contribution of the pial veins corrupting the la...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009