Fluorescent microspheres are superior to radioactive microspheres in chronic blood flow measurements.

نویسندگان

  • Matthijs F M Van Oosterhout
  • Frits W Prinzen
  • S Sakurada
  • Robb W Glenny
  • J Robert S Hales
چکیده

The accuracy of the fluorescent (FM) and radioactive microsphere (RM) techniques is similar in acute experiments but has not been established in chronic experiments. In the present study various combinations (at least pairs) of FM and/or RM labels were injected simultaneously between 2 mo and 5 min before each animal was killed. Blood flow was determined in many organs. Intramethod mean difference and variation did not change over time for FM but increased significantly for RM (from 1.8 ± 1.4 to 25.6 ± 21.8% and from 4.4 ± 3.2 to 32.4 ± 23.0% at 5 min and 2 mo, respectively). Also the FM-RM intermethod mean difference and variation increased (from -0.5 ± 8.5 to 40.8 ± 23.8% and from 23.6 ± 4.6 to 71.8 ± 34.3%, respectively). After 2 mo, blood flow estimations were 20-50% lower with the various RM, whereas brain and liver blood flow values varied even more between isotopes. Underestimation started within 1 day for51Cr and within 2 wk for141Ce,95Nb, and85Sr. We conclude that FM are superior to RM for blood flow determination in experiments lasting longer than 1 day, presumably because of leaching of isotopes from RM.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High spatial resolution measurements of organ blood flow in small laboratory animals.

With the use of a newly developed Imaging Cryomicrotome to determine the spatial location of fluorescent microspheres in organs, we validate and report our processing algorithms for measuring regional blood flow in small laboratory animals. Microspheres (15-microm diameter) of four different fluorescent colors and one radioactive label were simultaneously injected into the left ventricle of a p...

متن کامل

Evaluation of nonradioactive, colored microspheres for measurement of regional myocardial blood flow in dogs.

Measurement of regional myocardial blood flow (RMBF) is crucial in experimental studies of myocardial ischemia and reperfusion in dogs. The standard measurement technique uses radioactive microspheres; however, not all institutions are able to dispose of radioactive waste and therefore cannot make use of this method. We tested a new, nonradioactive microsphere, labeled with colors instead of nu...

متن کامل

Validation of fluorescent microsphere technique for measurement of organ perfusion with simplified sample processing method abbreviated title: sedimentation technique for fluorescent microspheres

A disadvantage of non-radioactive microsphere techniques is that the processing of samples is time consuming and complex. We developed and validated a simplified processing method for the fluorescent microsphere (FM) technique. In 7 anesthetized dogs with coronary artery stenosis up to 6 different FM and 5 different radioactively labeled microspheres (RM) were injected, 2 FM and 2 RM labels bei...

متن کامل

Stable labeled microspheres to measure perfusion: validation of a neutron activation assay technique.

Neutron activation is an accurate analytic method in which trace quantities of isotopes of interest in a sample are activated and the emitted radiation is measured with high-resolution detection equipment. This study demonstrates the application of neutron activation for the measurement of myocardial perfusion using stable isotopically labeled microspheres. Stable labeled and standard radiolabe...

متن کامل

Acute choke zone effects: Lessons from radioactive and fluorescent microspheres in a pig model muscle flap.

BACKGROUND Choke vessels dilate and contract to regulate blood flow between adjacent arterial angiosomes. In skin flap surgery, when arterial inflow to an angiosome is ligated, choke vessels allow blood supply from an adjacent angiosome. In muscle flap surgery, the vascular anatomy is analogous to skin flaps; however, while it is established that the choke vessels will fully dilate irreversibly...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 275 1  شماره 

صفحات  -

تاریخ انتشار 1998