A Quantitative Comparison of Unipolar and Augmented Unipolar Limb Leads

نویسنده

  • ERNST SIMONSoN
چکیده

Goldberger has claimed that his augmented unipolar limb leads (aV) are identical except for a 50 per cent larger amplitude and interchangeable with Wilson's original V leads, but this claim was not supported by quantitative evidence. The advantage of larger amplitudes explains the increasing preference for the aV leads. A quantitative comparison between V and aV leads revealed such tremendous variability of the augmentation ratio, both interindividual and between leads in the same individual, that standards obtained with V leads are not applicable to aV leads and vice versa. V leads and aV leads are not interchangeable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On Recording the Unipolar ECG Limb Leads via the Wilson's vs the Goldberger's Terminals: aVR, aVL, and aVF Revisited

The augmented unipolar limb leads aVR, aVL, and aVF, introduced by Goldberger in 1942, are an integral part of the 12-lead ECG.1,2 Leads I, II, and III have 2 dedicated electrodes, but the other 9 leads have a single dedicated electrode, and another one constructed from the averaged inputs of multiple electrodes. This Viewpoint discusses whether an indifferent pole for the recording of unipolar...

متن کامل

Appropriate leads in electrocardiography.

Before it is possible to assess the significance of any variation in the electrocardiographic tracing, it is necessary to know the appearances of the tracing in healthy subjects. Current practice is to record three standard limb leads, three augmented unipolar limb leads, and upwards of seven chest leads. In this way, minor variations from the normal are likely to be appreciated and more accura...

متن کامل

Appropriate Leads in Electrocardiography TABLE I BEHAVIOUR OF Q WAVE IN LEAD IIIR

Before it is possible to assess the significance of any variation in the electrocardiographic tracing, it is necessary to know the appearances of the tracing in healthy subjects. Current practice is to record three standard limb leads, three augmented unipolar limb leads, and upwards of seven chest leads. In this way, minor variations from the normal are likely to be appreciated and more accura...

متن کامل

The Unipolar Precordial and Extremity Electrocardiogram in Normal Infants and Children By MARIANO

Information regarding the normal unipolar electrocardiogram in the young ages is very limited. This study furnishes data obtained from 521 normal infants and children from birth to 13 years, using the V chest leads and the aV limb leads. Four age groups were noted in the evolution of the newborn pattern into the adult pattern as mainly reflected by the configuration of the QRS complex in V1. De...

متن کامل

The unipolar precordial and extremity electrocardiogram in normal infants and children.

Information regarding the normal unipolar electrocardiogram in the young ages is very limited. This study furnishes data obtained from 521 normal infants and children from birth to 13 years, using the V chest leads and the aV limb leads. Four age groups were noted in the evolution of the newborn pattern into the adult pattern as mainly reflected by the configuration of the QRS complex in V1. De...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005