Functional MRI with variable echo time acquisition.
نویسندگان
چکیده
A new functional MRI protocol that integrates variable echo time (TE) acquisition and a block-design paradigm is proposed and evaluated with finger-tapping motor task. Simulations and experimental data show that the blood oxygenation level-dependent (BOLD) sensitivity achieved with this approach is comparable to that achieved using a conventional constant-TE protocol. The proposed variable-TE fMRI protocol provides valuable information that cannot be obtained with the constant-TE protocol. First, a field inhomogeneity map can be derived from the multi-TE data and used to correct EPI geometric distortions. Second, changes of T2* values due to the BOLD effect can be quantified. Third, for brain regions with pronounced susceptibility field gradients, the reduced BOLD sensitivity may be compensated for when the acquired multi-TE data are processed appropriately (e.g., with weighted summation). Fourth, large venules and veins may possibly be identified (depending on the vessel orientation and volume fraction) by evaluating the phase values of the multi-TE data. Finally, magnetic field drift over time can be measured from dynamic field maps available with this protocol.
منابع مشابه
Variable Flip Angles and Echo Train Lengths in Segmented 3D-EPI at 3 and 7 Tesla
Purpose: To increase the signal sensitivity (temporal SNR/√acquisition time) of high-resolution functional MRI by means of two novel segmented 3D-EPI modifications: the use of variable flip angles (vFA) and, optionally, the use of variable echo train lengths (vETL) facilitated by employing elliptical k-space subsampling. While vFA has the potential to increase the base signal-to-noise ratio, vE...
متن کاملSupplementary methods and results for ” Decoding the large - scale structure of brain function by classifying mental states across individuals ”
Imaging was performed using a 3T Siemens AG (Erlangen, Germany) Allegra MRI scanner at the UCLA Ahmanson-Lovelace Brain Mapping Center. For all subjects, whole-brain functional imaging was performed using a T2*-weighted echoplanar imaging (EPI) sequence with common parameters [repetition time (TR), 2 s; echo time (TE), 30 ms; flip angle, 90; matrix, 64 x 64; field of view (FOV), 200 mm; slice t...
متن کاملAn investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter
Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...
متن کاملOptimized three-dimensional fast-spin-echo MRI.
Spin-echo-based acquisitions are the workhorse of clinical MRI because they provide a variety of useful image contrasts and are resistant to image artifacts from radio-frequency or static field inhomogeneity. Three-dimensional (3D) acquisitions provide datasets that can be retrospectively reformatted for viewing in freely selectable orientations, and are thus advantageous for evaluating the com...
متن کاملMulti Gradient Echo Acquisition Techniques for fMRI: Advantages of Bi-Exponential Modeling
Background: Functional MRI (fMRI) may benefit from techniques using multiple gradient echoes (1, 2). They allow the simultaneous measurement of the signal intensity I0 at TE=0 and the decay constant T2*. This yields separate quantification of the BOLDeffect from confounding signal changes of I0. Monoexponential models have been used to analyze the echo time dependence of the data. However, brai...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- NeuroImage
دوره 20 4 شماره