Biomechanical Integrity of Human Allograft Bone After Sterilization

نویسنده

  • Donna M.K. Squillace
چکیده

Musculoskeletal allografts have been used extensively for a variety of orthopaedic procedures. Allograft does have the potential, however, to transmit a variety of pathogens. Two current sterilization methods widely used in the tissue banking industry are ethylene oxide (ETO) treatment and gamma irradiation. ETO has been shown to adversely affect the biologic incorporation of allograft tissue. Gamma irradiation has been shown to have an adverse effect on the mechanical properties of tissue at certain doses. A novel sterilization process for allografts, the BioCleanse Tissue Sterilization Process, has been implemented that addresses the potential for disease transmission. Two studies, both using the BioCleanse process, were performed that examined the effects of various treatment regimes on the biomechanical properties of bone. The first study investigated effects of the BioCleanse process on the mechanical properties of bone. The second study evaluated bone through various processes, including the BioCleanse process combined with a terminal sterilization step in the final packaging. Figure 1. Studies found that after 5 minutes contact time (normal cycle: 218 minutes), The BioCleanse process completely perfused inner matrices of cortical and cancellous bone with sterilants.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Which is the best method of sterilization of tumour bone for reimplantation? a biomechanical and histopathological study

INTRODUCTION Sterilization and re-usage of tumour bone for reconstruction after tumour resection is now gaining popularity in the East. This recycle tumour bone needs to be sterilized in order to eradicate the tumour cells before re-implantation for limb salvage procedures. The effect of some of these treatments on the integrity and sterility of the bone after treatment has been published but t...

متن کامل

Effect of Chemical Sterilization on the Mechanical Properties of Human Cortical Bone Allografts

Introduction Musculoskeletal allografts are increasingly being utilized in a variety of orthopedic procedures. However, they pose the serious risk of viral or bacterial disease transmission as highlighted by the 2001 death of a young man from Clostridium sordellii sepsis after receiving a contaminated allograft. Gamma irradiation has been widely used to minimize this risk, but has been shown to...

متن کامل

Efficacy and Safety of Ethylene Oxide Sterilization of Allogeneic Bone for Human Transplantation: A Forty-Year Experience

Context: Since the year 2000, allogeneic tissues utilized for operations in humans in the United States have commonly undergone terminal sterilization with gamma irradiation. Ethylene oxide sterilization of tissues processed for human implantation has been abandoned Objectives: (1) To record the long-term successful experience of a precursor transplantation laboratory in the provision of human ...

متن کامل

Soft-tissue allografts terminally sterilized with an electron beam are biomechanically equivalent to aseptic, nonsterilized tendons.

BACKGROUND Allograft safety is contingent on effective sterilization. However, current sterilization methods have been associated with decreased biomechanical strength and higher failure rates of soft-tissue allografts. In this study, electron beam (e-beam) sterilization was explored as an alternative sterilization method to preserve biomechanical integrity. We hypothesized that e-beam steriliz...

متن کامل

Gamma Irradiated Soft Tissue Allografts are Biomechanically Equivalent to Aseptic, Non-Sterilized Tissues

Allograft safety is contingent on effective sterilization methods such as gamma irradiation. However, recent clinical studies have associated gamma irradiation with decreased graft strength and increased allograft failure rates, despite data that shows no deleterious effects to soft tissue biomechanics at gamma doses between 1.46 and 2.18 mRad. The objective of this study was to compare the bio...

متن کامل