Quantitative analysis of hydroperoxyl radical using flow injection analysis with chemiluminescence detection.

نویسندگان

  • Jun Zheng
  • Stephen R Springston
  • Judith Weinstein-Lloyd
چکیده

The hydroperoxyl radical (HO2) is one of the most abundant free radicals in the atmosphere, where it participates in a series of photochemical reactions that determine the fate of natural and anthropogenic emissions. In addition, HO2 is found in droplets and surface water as a result of photochemical formation and gas-phase scavenging. We describe a quantitative method for determining trace concentrations of HO2 radicals that exploits the chemiluminescence produced upon reaction with a synthetic analogue of luciferin from the crustacean Cypridina. The technique is linear at least up to 1 microM HO2(aq) and has a minimum detection limit of 0.1 nM. A unique feature of this analysis is a calibration method using stable aqueous HO2 standards produced in submicromolar concentrations using 60Co gamma-radiolysis. The advantage of this method in comparison to others in consideration of field deployment is its simplicity, low cost, and minimal size and power requirements. One intended application of this technique is the measurement of atmospheric HO2 radicals following collection into aqueous solution.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow Injection Technique for Biochemical Analysis with Chemiluminescence Detection in Acidic Media

A review with 90 references is presented to show the development of acidic chemiluminescence methods for biochemical analysis by use of flow injection technique in the last 10 years. A brief discussion of both the chemiluminescence and flow injection technique is given. The proposed methods for biochemical analysis are described and compared according to the used chemiluminescence system.

متن کامل

An overview on flow methods for the chemiluminescence determination of phosphorus.

A review on the flow analysis of phosphorus with chemiluminescence detection is presented. A brief discussion of the chemiluminescence principles and applications is given. Particular emphasis is devoted to coupling different flow techniques (flow injection, sequential injection, multicommutation, multisyringe flow injection, multi-pumping) to chemiluminescence detection. Enzymatic and non-enzy...

متن کامل

Determination of Total Antioxidant Activity of Wines Using a Flow Injection Method with Chemiluminescence Detection

Total antioxidant capacity (TAC) of several samples of red and white wines was investigated by means of a new analysis method of flow injection with chemiluminescence detection ((FIA-CL). The applied method is based on a chemiluminescence reaction between luminol and hydroxyl radicals generated by the hydrogen peroxide in the presence of Co(II) ions complexed with ethylene diamine tetraacetic a...

متن کامل

Flow injection chemiluminescence immunoassay of microcystin-LR by using PEI-modified magnetic beads as capturer and HRP-functionalized silica nanoparticles as signal amplifier.

A rapid sandwiched immunoassay of microcystin-LR (MC-LR) in water is proposed with flow injection chemiluminescence detection. The magnetic beads (MBs) were first modified with polyethyleneimine (PEI) by acylamide bond between the carboxyl group on the surface of MBs and the primary amine group in PEI, followed by immobilizing of anti-MC-LR (Ab1) onto PEI with glutaraldehyde as linkage. The res...

متن کامل

Development of an Evaluation Method for Hydroxyl Radical Scavenging Activities Using Sequential Injection Analysis with Chemiluminescence Detection.

A method for evaluating hydroxyl radical (·OH) scavenging activities using sequential injection analysis (SIA) with chemiluminescence (CL) detection was developed. In this system, CL was produced by the reaction of luminol with ·OH generated from the Fenton reaction. The scavenging activity was expressed as a diminution rate of the CL due to the scavenging of ·OH by a sample. The SIA system all...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 75 17  شماره 

صفحات  -

تاریخ انتشار 2003