BI Field Plots for a 3 Tesla Birdcage Coil: Concordance of Experimental and Theoretical Results
نویسندگان
چکیده
To compare the measured and the simulated radio frequency Bt distribution in cylindrical phantoms and in the head of healthy volunteers at 128 MHz. The experimental data were obtained with a 3 Tesla MRI research system equipped with a blrdcage coil. The simulated data were obtained with the Finite Difference Time Domain (FDTD) method of calculation for electromagnetics. MATERIAL AND METHODS the maximum) was 15 cm. In Fig. 1 are also reported the numerical EM simulation results along the radial dimension. There is very good agreement (<lo% deviation) between the calculation and one or the other side of the radial plots for every sample, with the exception of water which exhibits a small
منابع مشابه
Radio frequency magnetic field mapping of a 3 Tesla birdcage coil: experimental and theoretical dependence on sample properties.
The RF B(1) distribution was studied, theoretically and experimentally, in phantoms and in the head of volunteers using a 3 T MRI system equipped with a birdcage coil. Agreement between numerical simulation and experiment demonstrates that B(1) distortion at high field can be explained with 3D full-Maxwell calculations. It was found that the B(1) distribution in the transverse plane is strongly...
متن کاملRF Field Mapping of a High Field (3T) Birdcage Coil
INTRODUCTION Birdcage coils [l] are widely used for MRI studies of the human brain. Since anatomical constraints require a short birdcage coil (less than 35 cm), the RF field Bi inhomogeneities along the coil axis can be a limiting factor for image quality. Moreover, at high field (23T) numerical MRI results [2-31 show that the Bi is degraded because of strong interactions (inductive sample los...
متن کاملDesign and Simulation of a Birdcage Coil using CST Studio Suite for Application at 7T
This work describes the study of coil for Magnetic Resonance Imaging (MRI) application. Concretely, the principal objective is the design of a birdcage coil (RF coil) to use in a 7 Tesla scanner. More strength field has a better SNR and increased chemical shift effects, improving spectral fat suppression and spectroscopy. Moreover, a better SNR increases the spatial resolution or reduces the im...
متن کاملMagnetic Field Homogeneity of Birdcage Coil for 4T MRI System with No Lumped Circuit Elements
In recent years, magnetic resonance imaging (MRI) systems that operate up to under 3 T are being used in clinical practice in Japan. In order to achieve the requirements of higher image quality and shorter imaging times, devices that utilize high magnetic fields (> 3 T) and high power electromagnetic (EM) wave pulses have been developed. The rise of the static magnetic field is proportional to ...
متن کاملInvestigation of Parallel Radiofrequency Transmission for the Reduction of Heating in Long Conductive Leads in 3 Tesla Magnetic Resonance Imaging
Deep Brain Stimulation (DBS) is increasingly used to treat a variety of brain diseases by sending electrical impulses to deep brain nuclei through long, electrically conductive leads. Magnetic resonance imaging (MRI) of patients pre- and post-implantation is desirable to target and position the implant, to evaluate possible side-effects and to examine DBS patients who have other health conditio...