In situ analysis of trace elements in quartz by using laser ablation inductively coupled plasma mass spectrometry
نویسندگان
چکیده
There are several benefits which would result from the development of an in situ analytical technique for ultra trace elemental analysis of quartz, including rapid screening of possible high-purity quartz resources, by eliminating the need to remove solid and liquid inclusions by expensive dressing techniques prior to chemical analysis of structural impurities. Information on the petrogenetic history of the quartz can also be obtained from the distribution of trace elements. The main purpose of this paper is to describe an analytical method for estimating the concentrations of structural bounded trace elements in quartz. Ž A double focusing sector field inductively coupled plasma mass spectrometry ICP-MS, Finnigan MAT model . ELEMENT , with the CD-1 Guard Electrode and a 266-nm UV laser ablation system was used in the development of the method for in situ analysis of quartz. The following elements are included in the analytical protocol: Al, Ba, Be, Cr, Fe, Ge, K, Li, Mg, Mn, Pb, Rb, Sr, Th, Ž . Ž Ti, U. Analyses were carried out in low mass resolution mrDms300 , except for Mg, Ti, Cr, Fe medium mass . Ž . 29 resolution, MR, mrDmf3500 and K high mass resolution, HR, mrDm)8000 . The isotope Si was used as an internal standard at low resolution, and Si at medium and high resolution. External calibration was done by using the international reference materials: NIST 612, NIST 614, NIST 616, NIST 1830 from the National Institute of Standards and Technology Ž . Ž . NIST , BCS 313r1 from the Bureau of Analysed Samples BAS , the rhyolite RGM-1 reference sample from the United Ž . States Geological Survey USGS , Reston and the certified reference material Apure Substance No. 1B silicon dioxide SiO2 Ž . from the Federal Institute for Material Research and Testing, Berlin, Germany BAM . Because of the absence of an SiO2 blank, the BAM no. 1 SiO was used for the estimation of detection limits. Detection limits for most of the elements are 2 between 0.2 and 0.01 mg g. Analysis time and laser spot size were adjusted so that the raster did not exceed 300=300 Ž . mm on a 200-mm-thick section. New data for the international reference materials BCS 313r1 BAS and NIST 1830 and the standards BR-K1 and BR-FR2 are reported. To improve the lower limit of quantification and analytical uncertainty at low concentrations, it is important to have calibration curves with well defined intercepts. This can be achieved by the use of certified standards, with trace element concentrations lower than the BAM no.1 SiO or a sample blank. q 2002 Elsevier 2 Science B.V. All rights reserved.
منابع مشابه
کاربرد ترکیب عناصر جزئی کوارتز در تفسیر سنگزایی گرانیتوئیدهای نقده، شمال غربی زون سنندج- سیرجان
Trace elements distribution in granitic quartz is highly sensitive to differentiation processes. Abundance of Ti, Ge, Al and Li in primary quartz of Naqadeh granitoids have been studied by Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS). Trace elements ratio in quartz exhibits completely different trends in two different Naqadeh granitoid units (more mafic granitoids (MM...
متن کاملGreen and Fast Laser Fusion Technique for Bulk Silicate Rock Analysis by Laser Ablation-Inductively Coupled Plasma Mass Spectrometry.
Sample preparation of whole-rock powders is the major limitation for their accurate and precise elemental analysis by laser ablation inductively-coupled plasma mass spectrometry (ICPMS). In this study, a green, efficient, and simplified fusion technique using a high energy infrared laser was developed for major and trace elemental analysis. Fusion takes only tens of milliseconds for each sample...
متن کاملMultivariate pattern matching of trace elements in solids by laser ablation inductively coupled plasma-mass spectrometry: source attribution and preliminary diagnosis of fractionation.
Laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) is used with two variations of principal components analysis (PCA) for objective, routine comparisons of forensic materials without time-consuming and destructive sample dissolution. The relative concentrations of trace elements in a solid sample are examined to provide a "fingerprint" composition that can be used for identi...
متن کاملDetermination of Trace Elements in Sintered and Single-Crystal Silicon Carbide by Laser Ablation in Liquid Inductively Coupled Plasma Mass Spectrometry.
Laser ablation in liquid (LAL) sampling method transformed hard-to-digest materials to soluble particles, and thus allowed for smooth decomposition by acid digestion. LAL sampling is useful to generate nanoparticles from samples with less contamination. After acid digestion, trace elements in the LAL-sampled particles were analyzed by solution nebulization inductively coupled plasma mass spectr...
متن کاملAutomated in situ trace element analysis of silicate materials by laser ablation inductively coupled plasma mass spectrometry.
This paper describes the automated in situ trace element analysis of solid materials by laser ablation (LA) inductively coupled plasma mass spectrometry (ICP-MS). A compact computer-controlled solid state Nd:YAG Merchantek EO UV laser ablation (LA) system has been coupled with the high sensitivity VG PQII S ICP-MS. A two-directional communication was interfaced in-house between the ICP-MS and t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002