Acute Hemodynamic and Tissue Effects of Cryoballoon Ablation on Pulmonary Vessels: The IVUS‐Cryo Study
نویسندگان
چکیده
BACKGROUND Cryoballoon-based pulmonary vein isolation (CB-PVI) has been widely used for the treatment of atrial fibrillation. Although generally safe and effective, the procedure may be associated with pulmonary vein (PV) stenosis and bronchial or esophageal injury. The mechanisms leading to these complications have not been studied in detail. Our aim was to examine acute effects of cryoballoon on the pulmonary vessel and right heart pressures as well as PV wall morphology. METHODS AND RESULTS In 8 patients (5 men, mean age 55±14 years) undergoing CB-PVI, pressure in each PV was measured by catheter located inside the PV directly before and after CB-PVI. The right atrial, right ventricular, and pulmonary artery pressures as well as pulmonary arterial wedge capillary pressure in the pulmonary artery branch corresponding to target PV were also measured. Morphological changes in PVs were assessed using intravascular ultrasonography.There were no significant differences in PV pressures before and after ablation. The pulmonary arterial wedge capillary pressure significantly increased during cryoapplication (left superior: 20±10 versus 29±8.5 mm Hg, P=0.004; left inferior: 24±10 versus 32±6 mm Hg, P=0.012; right superior: 25±9 versus 35±10 mm Hg, P=0.002; right inferior: 24±10 versus 37±12 mm Hg, P=0.0036). The right atrial and pulmonary artery pressures increased significantly after CB-PVI (9±6 versus 13±8 mm Hg, P=0.004, and 20±9 versus 24±10 mm Hg, P=0.048, respectively). Intravascular ultrasonography showed acute edema and dissection-like changes causing relative lumen narrowing in 90% of PVs. CONCLUSIONS CB-PVI causes significant rise in pulmonary artery and right atrial pressures as well as PV wall damage. The clinical significance of these findings warrants further investigations.
منابع مشابه
Cryoballoon versus RF ablation in paroxysmal atrial fibrillation: results from the German Ablation Registry.
BACKGROUND Catheter ablation is used extensively with curative intention in atrial fibrillation. Radiofrequency ablation has long been a standard of care, while cryoballoon technology has emerged as a feasible approach with promising results. Prospective multicenter registry data referring to both ablation technologies in AF ablation therapy are lacking. METHODS Between January 2007 and Augus...
متن کاملEccentric scar formation around a pulmonary vein after cryo-balloon ablation in a patient with atrial fibrillation: A case report
The impact of a cryoballoon ablation is reported to be similar to that of a radiofrequency (RF) ablation in patients with atrial fibrillation. Delayed enhancement magnetic resonance imaging (DE-MRI) could visualize the scar region induced by the cryoballoon ablation as well as RF ablation. Cryoballoon ablation could induce extensive scar lesions around the PVs. However, the distribution of the ...
متن کاملAcute esophageal tissue reaction after Cryoballoon ablation in patients with paroxysmal atrial fibrillation - a LGE-MRI Study
Background Esophageal wall thermal injury after Cryoballoon ablation is a potentially serious complication. Late-Gadolinium Enhancement MRI (LGE-MRI) allows an accurate and non-invasive detection of acute tissue reaction. We thought to compare the relationsship of acute esophageal tissue reaction detected using LGE-MRI acute after pulmonary vein isolation (PVI) with the Arctic Front (AF) and th...
متن کاملMEDAFI-Trial (Micro-embolization during ablation of atrial fibrillation): comparison of pulmonary vein isolation using cryoballoon technique vs. radiofrequency energy.
AIMS Cerebral embolism is a possible serious complication during catheter ablation of atrial fibrillation (AF). The purpose of this prospective pilot study was to analyse the incidence and possible impact of cryo ablation on cerebral lesions and possible differences to radiofrequency (RF) ablation during pulmonary vein isolation (PVI). METHODS AND RESULTS Pulmonary vein isolation was performe...
متن کاملBiophysics of the second-generation cryoballoon: cryobiology of the big freeze.
C urrent guidelines recommend antral isolation of the pulmonary veins (PV) as the cornerstone of atrial fibrillation ablation. 1 Although conventional radiofrequency energy has traditionally been used with a point-by-point approach, cryo-ablation has emerged as a viable alternative to radiofrequency energy. The clinical success of cryoablation has been driven by the introduction of the cryoball...