In situ and ex vivo evaluation of a wireless magnetoelastic biliary stent monitoring system.
نویسندگان
چکیده
This paper presents the in situ and ex vivo evaluation of a system that wirelessly monitors the accumulation of intimal tissue and sludge in a biliary stent. The sensing element, located within the stent, is a magnetoelastic resonator that is queried by a wireless radio frequency signal. The in situ testing uses a commercially-available self-expanding biliary stent enhanced with a 1 mm x 25 mm magnetoelastic ribbon sensor (formed from Metglas 2605SA1). The stent has a conformal magnetic layer (consisting of strontium ferrite particles suspended in polydimethylsiloxane) that biases the sensor. The external interrogation module is able to acquire a signal from the sensor from a distance of at least 5 cm while the sensor is implanted in a porcine carcass and loaded with biological fluids. The ex vivo testing uses bile harvested from the porcine carcass. The response of a 1 mm x 25 mm magnetoelastic ribbon sensor is first calibrated with fluids of known density and viscosity, and the calibrated sensor is used to estimate that the viscosity of the harvested bile is 2.7-3.7 cP. The test results presented in this paper illustrate the fundamental usability of the system when the sensor is implanted, loaded by biological fluids, and interrogated in a surgical setup.
منابع مشابه
In vivo and in situ evaluation of a wireless magnetoelastic sensor array for plastic biliary stent monitoring.
This paper presents the in vivo and in situ evaluation of a system that wirelessly monitors the accumulation of biliary sludge in a plastic biliary stent. The sensing element, located within the stent, is a passive array of magnetoelastic resonators that is queried by a wireless electromagnetic signal. The in vivo and in situ testing uses commercially-available plastic biliary stents, each enha...
متن کاملTailored magnetoelastic sensor geometry for advanced functionality in wireless biliary stent monitoring systems
This paper presents three types of wireless magnetoelastic resonant sensors with specific functionalities for monitoring sludge accumulation within biliary stents. The first design uses a geometry with a repeated cell shape that provides two well-separated resonant mode shapes and associated frequencies to permit spatial localization of mass loading. The second design implements a pattern with ...
متن کاملTailored magnetoelastic sensor geometry for wireless biliary stent monitoring
This paper presents three types of wireless magnetoelastic resonant sensors with specific functionalities for monitoring sludge accumulation within biliary stents. The first design uses a geometry with a repeated cell shape that provides two well-separated resonant mode shapes and associated frequencies to permit spatial localization of mass loading. The second design implements a pattern with ...
متن کاملExploring the potential of complex-vesicle based niosomal ocular system loaded with azithromycin: Development of in situ gel and ex vivo characterization
Abstract Bacterial conjunctivitis characterized as pink eye referred as an inflammation of an eye caused by the enlargement of blood vessels present in conjunctiva, resulting in a red or bloodshot appearance of the eyes. Topical ocular delivery is found to be useful in treating conjunctivitis, but to maintain an effective drug concentration at a site of action in order to achieve desired pha...
متن کاملToward an implantable wireless cardiac monitoring platform integrated with an FDA-approved cardiovascular stent.
Continuous monitoring of blood pressure from a minimally invasive device in the pulmonary artery can serve as a diagnostic and early warning system for cardiac health. The foremost challenge in such a device is the wireless transfer of data and power from within the blood vessel to an external device while maintaining unrestricted flow through the artery. We present a miniaturized system, which...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biomedical microdevices
دوره 12 3 شماره
صفحات -
تاریخ انتشار 2010