Spatiotemporal electrophysiological changes in a murine ablation model.
نویسندگان
چکیده
AIMS High recurrence rates after complex radiofrequency ablation procedures, such as for atrial fibrillation, remain a major clinical problem. Local electrophysiological changes that occur following cardiac ablation therapy are incompletely described in the literature. The purpose of this study was to determine whether alterations in conduction velocity, action potential duration (APD), and effective refractory period resolve dynamically following cardiac ablation. METHODS AND RESULTS Lesions were delivered to the right ventricle of mice using a subxiphoid approach. The sham-operated control group (SHAM) received the same procedure without energy delivery. Hearts were isolated at 0, 1, 7, 30, and 60 days following the procedure and electrophysiological parameters were obtained using high-resolution optical mapping with a voltage-sensitive dye. Conduction velocity was significantly decreased at the lesion border in the 0, 7, and 30 day groups compared to SHAM. APD(70) at the lesion border was significantly increased at all time points compared to SHAM. Effective refractory period was significantly increased at the lesion border at 0, 1, 7, and 30 days but not at 60 days post-ablation. This study demonstrated that post-ablation electrophysiological changes take place immediately following energy delivery and resolve within 60 days. CONCLUSIONS Cardiac ablation causes significant electrophysiological changes both within the lesion and beyond the border zone. Late recovery of electrical conduction in individual lesions is consistent with clinical data demonstrating that arrhythmia recurrence is associated with failure to maintain bi-directional conduction block.
منابع مشابه
Frequency-dependent electrophysiological properties of concealed slow pathway of isolated rabbit atrioventricular node preparation after fast pathway ablation in a functional model
Introduction: Intranodal pathways of atrioventricular (AV) node play a vital role in the delay of conduction time in response to various atrial inputs. The present study was aimed to determine the frequency-dependent electrophysiological properties of concealed slow pathway according to a functional model of isolated rabbit atrioventricular node preparation after fast pathway ablation. Meth...
متن کاملNew model of computer analysis for assessment of the effects of lesions induced by direct voltage current in isolated AV-node of rabbit
Introduction: The ablation technique is one of the important therapeutic interventions for treatment of AV Nodal tachyarrhythmia. Different animal models have been developed to study the effects of ablation on the functional interanodal structure. The aim of the present study was to develop a new model of computer analysis to produce lesions by using direct voltage in isolated perfused rabbi...
متن کاملEffect of the preparation program on the anxiety of candidate patients for cardiac electrophysiological interventions: A randomized clinical trial
Introduction: Patients' anxiety in cardiac electrophysiological studies (EPS) and ablation due to its unknown aspects needs more attention and the necessary measures to reduce it. The aim of this study was to determine the effect of the preparation program on patients' anxiety waiting for these interventions. Materials and Methods: This clinical trial was carried out in parallel with the partic...
متن کاملEffects Of Fast Pathway Ablation On The Concealment Zone And Electrophysiological Behavior Of AV-Node During Atrial Fibrillation.
Objectives: Dual pathways have a determinant role in the occurrence of atrio nodal tachyarrhythmia (AVNRT). The aim of present study is to determine the role of slow pathway (SP) in the concealment zone and protective role of AV node during atrial fibrillation (AF). Material &Methods: In 7 isolated nodal rabbit preparation zone of concealment and concealed conduction is quantified by Specif...
متن کاملPET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors
Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
دوره 13 10 شماره
صفحات -
تاریخ انتشار 2011