Retinal Vascular and Oxygen Temporal Dynamic Responses to Light Flicker in Humans

نویسندگان

  • Anthony E. Felder
  • Justin Wanek
  • Norman P. Blair
  • Mahnaz Shahidi
چکیده

Purpose To mathematically model the temporal dynamic responses of retinal vessel diameter (D), oxygen saturation (SO2), and inner retinal oxygen extraction fraction (OEF) to light flicker and to describe their responses to its cessation in humans. Methods In 16 healthy subjects (age: 60 ± 12 years), retinal oximetry was performed before, during, and after light flicker stimulation. At each time point, five metrics were measured: retinal arterial and venous D (DA, DV) and SO2 (SO2A, SO2V), and OEF. Intra- and intersubject variability of metrics was assessed by coefficient of variation of measurements before flicker within and among subjects, respectively. Metrics during flicker were modeled by exponential functions to determine the flicker-induced steady state metric values and the time constants of changes. Metrics after the cessation of flicker were compared to those before flicker. Results Intra- and intersubject variability for all metrics were less than 6% and 16%, respectively. At the flicker-induced steady state, DA and DV increased by 5%, SO2V increased by 7%, and OEF decreased by 13%. The time constants of DA and DV (14, 15 seconds) were twofold smaller than those of SO2V and OEF (39, 34 seconds). Within 26 seconds after the cessation of flicker, all metrics were not significantly different from before flicker values (P ≥ 0.07). Conclusions Mathematical modeling revealed considerable differences in the time courses of changes among metrics during flicker, indicating flicker duration should be considered separately for each metric. Future application of this method may be useful to elucidate alterations in temporal dynamic responses to light flicker due to retinal diseases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inner Retinal Oxygen Extraction Fraction in Response to Light Flicker Stimulation in Humans.

PURPOSE Light flicker has been shown to stimulate retinal neural activity, increase blood flow, and alter inner retinal oxygen metabolism (MO2) and delivery (DO2). The purpose of the study was to determine the change in MO2 relative to DO2 due to light flicker stimulation in humans, as assessed by the inner retinal oxygen extraction fraction (OEF). METHODS An optical imaging system, based on ...

متن کامل

Investigating the frequency characteristics of the electroretinogram signal in patients with central retinal vein occlusion

Background: Central retinal vein occlusion (CRVO) is the second most common retinal vascular disorder after diabetic retinopathy. In this study, we tried to examine the potentials of time-frequency methods for differentiating the eyes with CRVO. Materials and methods: Twenty patients with unilateral CRVO were included in this study. Their contralateral normal eyes were considered as the control...

متن کامل

Dynamic responses in retinal vessel caliber with flicker light stimulation in eyes with diabetic retinopathy.

PURPOSE This study investigated the responses of retinal vessels to flickering light in diabetic patients with various stages of diabetic retinopathy (DR). METHODS This cross-sectional observational study evaluated adult subjects with diabetes mellitus. The Dynamic Vessel Analyzer (DVA) was used to measure retinal vascular dilatation in response to diffuse illuminance flicker. Diabetic retino...

متن کامل

Evaluation of retinal function and flicker light-induced retinal vascular response in normotensive patients with diabetes without retinopathy.

PURPOSE To correlate retinal function with vascular response to flicker light in normotensive patients with diabetes without diabetic retinopathy (DR). METHODS Twenty-eight normotensive patients with diabetes (11 with type 1, 17 with type 2) without DR and 28 sex- and age-matched healthy control subjects underwent color vision and contrast sensitivity testing, pattern, full-field, and multifo...

متن کامل

Diffuse luminance flicker increases retinal vessel diameter in humans.

PURPOSE To determine retinal vessel diameter variations in response to neuronal activity induced by diffuse luminance flicker. METHODS The diameter of retinal arteries and veins was measured in 9 normal subjects by computer analysis of fundus pictures taken in monochromatic light under normal conditions of illumination and after 1 min of sinusoidally varying diffuse luminance flicker at 10 Hz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 58  شماره 

صفحات  -

تاریخ انتشار 2017